NATURAL LUTETIUM RADIOACTIVITY IN PET DEVICES WITH LUTETIUM SCINTILATION DETECTORS: INFLUENCE ON THE DIAGNOSTIC RESULT, CALIBRATION AND THE ENVIRONMENT

Today's standard PET (Positron Emission Tomography) scanners use scintillation detectors based on lutetium, which contain the Lu-176 radioisotope. In this paper, the mass fraction and relevant radioactivity of this isotope were explicitly calculated using a commercial device as an example. The analysis of the obtained result examined and discussed its impact on clinical work, the calibration procedures of PET scanners, as well as the safety and health of exposed workers, the general population, and the environment, including the period after the device is no longer in use.

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.46793/hse25.206a
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NATURAL LUTETIUM RADIOACTIVITY IN PET DEVICES WITH LUTETIUM SCINTILATION DETECTORS: INFLUENCE ON THE DIAGNOSTIC RESULT, CALIBRATION AND THE ENVIRONMENT

Radiation Dose and Imaging
article

NATURAL LUTETIUM RADIOACTIVITY IN PET DEVICES WITH LUTETIUM SCINTILATION DETECTORS: INFLUENCE ON THE DIAGNOSTIC RESULT, CALIBRATION AND THE ENVIRONMENT

article en

Abstract

Today's standard PET (Positron Emission Tomography) scanners use scintillation detectors based on lutetium, which contain the Lu-176 radioisotope. In this paper, the mass fraction and relevant radioactivity of this isotope were explicitly calculated using a commercial device as an example. The analysis of the obtained result examined and discussed its impact on clinical work, the calibration procedures of PET scanners, as well as the safety and health of exposed workers, the general population, and the environment, including the period after the device is no longer in use.

Openalex Percentile: Top 78%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

NATURAL LUTETIUM RADIOACTIVITY IN PET DEVICES WITH LUTETIUM SCINTILATION DETECTORS: INFLUENCE ON THE DIAGNOSTIC RESULT, CALIBRATION AND THE ENVIRONMENT · (2025) | TGRS Research Map | TGRS