Bilateral comparison in high gauge pressure 250 MPa

Main text CMI and GUM agreed a bilateral comparison in high gauge pressure up to 250 MPa in oil medium. This comparison was initiated as EURAMET Project No. 1375 and obtained a designation EURAMET.M.P-S16. A direct comparison method was used - a pressure balance of GUM reference standard was compared to a pressure balance of CMI. There were no discrepant measurements (with the resultant standardised equivalence degrees between 0.15 and 0.88) and CMI and GUM confirmed their equivalence. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-01-01
DOI
https://doi.org/10.1088/0026-1394/62/1a/07014
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bilateral comparison in high gauge pressure 250 MPa

Adam Brzozowski, Richard Páviš, Dominik Pražák
Metrologia
Scientific Measurement and Uncertainty Evaluation
article

Bilateral comparison in high gauge pressure 250 MPa

Adam Brzozowski, Richard Páviš, Dominik Pražák
article en

Abstract

Main text CMI and GUM agreed a bilateral comparison in high gauge pressure up to 250 MPa in oil medium. This comparison was initiated as EURAMET Project No. 1375 and obtained a designation EURAMET.M.P-S16. A direct comparison method was used - a pressure balance of GUM reference standard was compared to a pressure balance of CMI. There were no discrepant measurements (with the resultant standardised equivalence degrees between 0.15 and 0.88) and CMI and GUM confirmed their equivalence. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

MetrologiaVol. 62(1A)
Český metrologický institut (CZ), Central Office of Measures (PL)
Partnerships for the goals
Openalex Percentile: Top 86%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.