Whole heart perfusion with high‐multiband Simultaneous Multislice Imaging via Linear phase modulated Extended field of view (SMILE)
The theoretical derivation and experimental results validate the SMILE's improved performance at high acceleration and MB as compared to the existing 2D CAIPI SMS acquisition and reconstruction techniques for first-pass myocardial perfusion imaging.
Authors
- Junyu Wang (ORCID: https://orcid.org/0000-0001-8314-4525)
- Shen Zhao
- Sizhuo Liu (ORCID: https://orcid.org/0000-0002-3248-0737)
- Michael Salerno (ORCID: https://orcid.org/0000-0001-7051-1031)
- Quan Chen (ORCID: https://orcid.org/0000-0002-5392-8000)
- Xitong Wang (ORCID: https://orcid.org/0009-0002-8457-9189)
- Yoo Jin Lee (ORCID: https://orcid.org/0009-0008-2348-2520)
- Kevin Kai Li
Institutions
- University of California, San Francisco (US)
- University of California System (US)
- Stanford University (US)
Publication Details
- Journal
- Magnetic Resonance in Medicine
- Published
- 2025-06-22
- DOI
- https://doi.org/10.1002/mrm.30541
- Citations
- 1
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.36
Funders
- National Institutes of Health