Evaluasi Bangunan Gedung Existing terhadap Penambahan Beban Cathlab (Studi Kasus: RSAU Antariksa Halim Perdana Kusuma)

Rumah Sakit Angkatan Udara (RSAU) Antariksa Halim Perdana Kusuma is a type B hospital equipped with a Cath Lab. In 2022, the management planned to add more Cath Lab equipment and supporting facilities, prompting a structural evaluation according to SNI 1726:2019 and SNI 2847:2019. This analysis employed various methods and field data, aiming to recommend service improvements while ensuring safety compliance. The study investigated the building's structural condition through visual inspection and concrete quality audits using Hammer and UPV tests. The results showed no structural damage but varied concrete quality. The analysis using the lowest concrete quality confirmed the building's load-bearing capacity according to standards, though it did not meet SMRF requirements, necessitating reinforcement. Additional analysis revealed shear capacity failures due to the increased load. It is advised not to expand the Cath Lab area at the specified location.

Authors

Institutions

Publication Details

Journal
Jurnal Praktik Keinsinyuran.
Published
2024-10-12
DOI
https://doi.org/10.25170/jpk.v1i03.6429
Primary Topic
Occupational Health and Safety Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluasi Bangunan Gedung Existing terhadap Penambahan Beban Cathlab (Studi Kasus: RSAU Antariksa Halim Perdana Kusuma)

Wibawa Gede Arya, Yanto Yanto
Jurnal Praktik Keinsinyuran.
Occupational Health and Safety Management
article

Evaluasi Bangunan Gedung Existing terhadap Penambahan Beban Cathlab (Studi Kasus: RSAU Antariksa Halim Perdana Kusuma)

Wibawa Gede Arya, Yanto Yanto
article en

Abstract

Rumah Sakit Angkatan Udara (RSAU) Antariksa Halim Perdana Kusuma is a type B hospital equipped with a Cath Lab. In 2022, the management planned to add more Cath Lab equipment and supporting facilities, prompting a structural evaluation according to SNI 1726:2019 and SNI 2847:2019. This analysis employed various methods and field data, aiming to recommend service improvements while ensuring safety compliance. The study investigated the building's structural condition through visual inspection and concrete quality audits using Hammer and UPV tests. The results showed no structural damage but varied concrete quality. The analysis using the lowest concrete quality confirmed the building's load-bearing capacity according to standards, though it did not meet SMRF requirements, necessitating reinforcement. Additional analysis revealed shear capacity failures due to the increased load. It is advised not to expand the Cath Lab area at the specified location.

Jurnal Praktik Keinsinyuran.Vol. 1(03)
Atma Jaya Catholic University of Indonesia (ID)
Sustainable cities and communities
Openalex Percentile: Top 47%
Occupational Health and Safety Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluasi Bangunan Gedung Existing terhadap Penambahan Beban Cathlab (Studi Kasus: RSAU Antariksa Halim Perdana Kusuma) — Wibawa Gede Arya, Yanto Yanto · Jurnal Praktik Keinsinyuran. (2024) | TGRS Research Map | TGRS