Evaluation of the Connections of Dıfferent Type of Abutments to the Implant Body Under Mastication

Objective: This study aims to compare the biomechanical behavior of the implant-abutment connection against in-vitro loading in the use of Straight and Angled standard fabricated abutments and CAD/CAM abutments in a locally designed and produced special connection. Materials and Methods:Ti Grade5 Straight abutment was used in the first group, 25° Angled Ti Grade5 fabricated abutment was used in the 2nd Group, and TiBase abutment was used in the 3rd Group. The implant diameter was used as 4.8 mm, and each sample was fixed on the implant manually or using a torque wrench. The crowns were cemented or screwed to the superstructures, which were torqued or manually tightened to 30 Ncm twice a day apart, and the first images were taken with the Micro-CT device. Four-year use of each sample was simulated in 1000000 cycles in the chewing simulator application. Micro-CT was again used to measure implant-abutment contact areas after loading. Results: There is a significant difference between all groups, except for the range in the tightening group with 30Ncm torque before simulation, only on one side and at the internal measurement point. Conclusion: When we look at the compatibility of the connection screw with the abutment before and after the chewing simulation; In general, it has been noticed that the fabricated straight abutments and Universal Ti-Base abutments have a tighter connection gap, while the connection of Angled abutments is weaker. When looking at the compatibility of the abutment contact areas with the implant body before and after the chewing simulation; It has been observed that the tightest connection values are generally created by CAD/CAM and Straight abutments, to a greater extent than screw fit.

Authors

Institutions

Publication Details

Journal
Meandros Medical And Dental Journal
Published
2025-06-22
DOI
https://doi.org/10.69601/meandrosmdj.1599847
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Connections of Dıfferent Type of Abutments to the Implant Body Under Mastication

Kaan Orhan, Bora Akat, Burak Bilecenoğlu, Yezdan Dilan Erkcan et al.
Meandros Medical And Dental Journal
Dental Implant Techniques and Outcomes
article

Evaluation of the Connections of Dıfferent Type of Abutments to the Implant Body Under Mastication

Kaan Orhan, Bora Akat, Burak Bilecenoğlu, Yezdan Dilan Erkcan, Mehmet Ali Kılıçarslan
article en

Abstract

Objective: This study aims to compare the biomechanical behavior of the implant-abutment connection against in-vitro loading in the use of Straight and Angled standard fabricated abutments and CAD/CAM abutments in a locally designed and produced special connection. Materials and Methods:Ti Grade5 Straight abutment was used in the first group, 25° Angled Ti Grade5 fabricated abutment was used in the 2nd Group, and TiBase abutment was used in the 3rd Group. The implant diameter was used as 4.8 mm, and each sample was fixed on the implant manually or using a torque wrench. The crowns were cemented or screwed to the superstructures, which were torqued or manually tightened to 30 Ncm twice a day apart, and the first images were taken with the Micro-CT device. Four-year use of each sample was simulated in 1000000 cycles in the chewing simulator application. Micro-CT was again used to measure implant-abutment contact areas after loading. Results: There is a significant difference between all groups, except for the range in the tightening group with 30Ncm torque before simulation, only on one side and at the internal measurement point. Conclusion: When we look at the compatibility of the connection screw with the abutment before and after the chewing simulation; In general, it has been noticed that the fabricated straight abutments and Universal Ti-Base abutments have a tighter connection gap, while the connection of Angled abutments is weaker. When looking at the compatibility of the abutment contact areas with the implant body before and after the chewing simulation; It has been observed that the tightest connection values are generally created by CAD/CAM and Straight abutments, to a greater extent than screw fit.

Meandros Medical And Dental JournalVol. 26(2)
Ankara University (TR), Istanbul Medipol University (TR), Ankara Medipol Üniversitesi
Openalex Percentile: Top 80%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.