Evaluation of the Proximal Radio-Ulnar Joint Anatomy as a Marker for Radial Head Arthroplasty

Objectives Implant sizing is a challenging step in radial head arthroplasty. Improper selection can “overstuff” the elbow joint and lead to degenerative changes. Prior investigation with computed tomography demonstrated a consistent relationship between the radial head and coronoid, which can guide implant sizing. We hypothesize that conventional radiography can similarly define the radioulnar variance at the proximal radioulnar joint (PRUJ) and serve as a landmark for radial head replacement. Methods Patients with elbow radiographs were eligible for the study. Patients who had trauma from the humeral shaft to the distal radius were excluded. Anteroposterior projections were performed in full extension and supination. One orthopaedic hand specialist, one senior resident, and one junior resident assessed the radiographs for coronoid to radial head height, defined as the distance from the equator of the radial head projection to the top of the coronoid projection. Results Fifty elbow radiographs were consecutively selected for radiographic study. There were 37 (74%) males and 13 (26%) females, with a mean age of 40. The average coronoid-radial head distance was 2.2mm (SD 1.5mm), ranging from -2.6 to 5.2mm. Interobserver reliability was 0.95. Conclusions Our data shows that the radiographic anatomy of the PRUJ shows a consistent relationship between the coronoid and radial head. This measurement is reliably reproducible and may be used as a marker of radial head placement and sizing in radial head arthroplasty, reducing cost and radiation exposure. This study presents an alternative reference point to measure radial head variance to assess for overstuffing during radial head arthroplasty.

Authors

Institutions

Publication Details

Journal
SurgiColl
Published
2025-06-22
DOI
https://doi.org/10.58616/001c.130861
Primary Topic
Elbow and Forearm Trauma Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Proximal Radio-Ulnar Joint Anatomy as a Marker for Radial Head Arthroplasty

Dominick V. Congiusta, Robert L DalCortivo, Michael M. Vosbikian, Omkar Baxi et al.
SurgiColl
Elbow and Forearm Trauma Treatment
article

Evaluation of the Proximal Radio-Ulnar Joint Anatomy as a Marker for Radial Head Arthroplasty

Dominick V. Congiusta, Robert L DalCortivo, Michael M. Vosbikian, Omkar Baxi, David Ahn, Irfan Ahmed
article en

Abstract

Objectives Implant sizing is a challenging step in radial head arthroplasty. Improper selection can “overstuff” the elbow joint and lead to degenerative changes. Prior investigation with computed tomography demonstrated a consistent relationship between the radial head and coronoid, which can guide implant sizing. We hypothesize that conventional radiography can similarly define the radioulnar variance at the proximal radioulnar joint (PRUJ) and serve as a landmark for radial head replacement. Methods Patients with elbow radiographs were eligible for the study. Patients who had trauma from the humeral shaft to the distal radius were excluded. Anteroposterior projections were performed in full extension and supination. One orthopaedic hand specialist, one senior resident, and one junior resident assessed the radiographs for coronoid to radial head height, defined as the distance from the equator of the radial head projection to the top of the coronoid projection. Results Fifty elbow radiographs were consecutively selected for radiographic study. There were 37 (74%) males and 13 (26%) females, with a mean age of 40. The average coronoid-radial head distance was 2.2mm (SD 1.5mm), ranging from -2.6 to 5.2mm. Interobserver reliability was 0.95. Conclusions Our data shows that the radiographic anatomy of the PRUJ shows a consistent relationship between the coronoid and radial head. This measurement is reliably reproducible and may be used as a marker of radial head placement and sizing in radial head arthroplasty, reducing cost and radiation exposure. This study presents an alternative reference point to measure radial head variance to assess for overstuffing during radial head arthroplasty.

SurgiCollVol. 3(2)
Rutgers, The State University of New Jersey (US), Kaiser Permanente Capitol Hill Medical Center (US), Rutgers New Jersey Medical School (US)
Openalex Percentile: Top 82%
Elbow and Forearm Trauma Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.