Well-Type Xenon Gamma-Ray Spectrometer

Modern gamma-ray spectrometers should exhibit high spectrometric characteristics (energy resolution, efficiency, radiation resistance, operating temperature range, and energy consumption), which provide a possibility of their use in various scientific studies, including nuclear medicine. This paper is devoted to the development of a well-type xenon gamma-ray spectrometer (WT-XGRS) for measuring the gamma activity of pharmaceuticals and determining their isotopic composition. The general design of this device is developed using the parametric computer-aided design modeler (FreeCAD). Using the Monte Carlo method (Geant4 package), model experiments are performed to determine the main physical characteristics of the fabricated equipment. The radioisotope Ba-133 is used as a gamma-ray source. The dependence of the registration efficiency of gamma quanta on their energy for a WT-XGRS, as well as on the location of the point radioactive pharmaceutical inside the well, is obtained. The calculated results are analyzed and the possibility of using this equipment in the field of nuclear medicine is considered.

Authors

Institutions

Publication Details

Journal
Bulletin of the Lebedev Physics Institute
Published
2025-05-01
DOI
https://doi.org/10.3103/s1068335624602267
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Well-Type Xenon Gamma-Ray Spectrometer

A. E. Shustov, A. I. Madzhidov, R. R. Egorov, V. V. Dmitrenko et al.
Bulletin of the Lebedev Physics Institute
Nuclear Physics and Applications
article

Well-Type Xenon Gamma-Ray Spectrometer

A. E. Shustov, A. I. Madzhidov, R. R. Egorov, V. V. Dmitrenko, V. M. Grachev, S. E. Ulin, K. F. Vlasik, Z. M. Uteshev, N. M. Sveshnikov
article en

Abstract

Modern gamma-ray spectrometers should exhibit high spectrometric characteristics (energy resolution, efficiency, radiation resistance, operating temperature range, and energy consumption), which provide a possibility of their use in various scientific studies, including nuclear medicine. This paper is devoted to the development of a well-type xenon gamma-ray spectrometer (WT-XGRS) for measuring the gamma activity of pharmaceuticals and determining their isotopic composition. The general design of this device is developed using the parametric computer-aided design modeler (FreeCAD). Using the Monte Carlo method (Geant4 package), model experiments are performed to determine the main physical characteristics of the fabricated equipment. The radioisotope Ba-133 is used as a gamma-ray source. The dependence of the registration efficiency of gamma quanta on their energy for a WT-XGRS, as well as on the location of the point radioactive pharmaceutical inside the well, is obtained. The calculated results are analyzed and the possibility of using this equipment in the field of nuclear medicine is considered.

Bulletin of the Lebedev Physics InstituteVol. 52(5)
National Research Nuclear University MEPhI (RU)
Openalex Percentile: Top 80%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Well-Type Xenon Gamma-Ray Spectrometer — A. E. Shustov, A. I. Madzhidov, et al. · Bulletin of the Lebedev Physics Institute (2025) | TGRS Research Map | TGRS