Background One of the notable challenges in implant dentistry is the inadequacy of bone dimensions. While guided bone regeneration remains the standard approach for horizontal bone reconstruction, emerging new approaches such as the shell technique offer the potential for significant bone gain through effective space creation. This article presents a modified shell technique as a promising and practitioner-friendly solution for managing horizontal bone deficiencies before and during implant placement. This article aims to introduce a simplified and minimally invasive approach that enhances space maintenance and surgical management and allows for extraoral screw fixation to the disc with just a single screw. Methodology This study included six patients with horizontal bone defects that made them candidates for bone augmentation procedures. We employed a newly modified shell technique utilizing a single-screw cortical disc. The cortical discs were fabricated from cortical plates using a trephine drill and Cortico-Cage device. A titanium screw was secured extraorally to the cortical disc. The assembly of the screw and disc was anchored bi-cortically in the appropriate position, and the gap between the cortical disc and the underlying bone bed was filled with a combination of autogenous chips and allograft material. This simplified shell technique is designed to facilitate bone augmentation in areas with horizontal bone deficiencies. Results Cone-beam computed tomography assessments performed five months postoperatively in five cases demonstrated that the increase in bone width at the crestal area, specifically at the site of cortical discs, ranged from a minimum of 2.03 mm to a maximum of 5.76 mm. Moreover, the initial bone width before reconstruction in the evaluated cases ranged from a minimum of 1.74 mm to a maximum of 4.40 mm. Radiographs before and after the procedure indicated a noteworthy bone formation. Conclusions The findings suggest that employing a single screw to secure the cortical disc while connecting it to the disc outside of the patient's oral cavity can facilitate the surgical process and enhance patient comfort.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-06-21
DOI
https://doi.org/10.7759/cureus.86475
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using a Single-Screw Cortical Disc for a Simplified Shell Technique: A Novel Approach and Technical Note

Fatemeh Goudarzimoghaddam, Mehdi Ekhlasmandkermani, Mohammad Sabet Jahromi, Emir Ilkerli
Cureus
Dental Implant Techniques and Outcomes
article

Using a Single-Screw Cortical Disc for a Simplified Shell Technique: A Novel Approach and Technical Note

Fatemeh Goudarzimoghaddam, Mehdi Ekhlasmandkermani, Mohammad Sabet Jahromi, Emir Ilkerli
article en

Abstract

Background One of the notable challenges in implant dentistry is the inadequacy of bone dimensions. While guided bone regeneration remains the standard approach for horizontal bone reconstruction, emerging new approaches such as the shell technique offer the potential for significant bone gain through effective space creation. This article presents a modified shell technique as a promising and practitioner-friendly solution for managing horizontal bone deficiencies before and during implant placement. This article aims to introduce a simplified and minimally invasive approach that enhances space maintenance and surgical management and allows for extraoral screw fixation to the disc with just a single screw. Methodology This study included six patients with horizontal bone defects that made them candidates for bone augmentation procedures. We employed a newly modified shell technique utilizing a single-screw cortical disc. The cortical discs were fabricated from cortical plates using a trephine drill and Cortico-Cage device. A titanium screw was secured extraorally to the cortical disc. The assembly of the screw and disc was anchored bi-cortically in the appropriate position, and the gap between the cortical disc and the underlying bone bed was filled with a combination of autogenous chips and allograft material. This simplified shell technique is designed to facilitate bone augmentation in areas with horizontal bone deficiencies. Results Cone-beam computed tomography assessments performed five months postoperatively in five cases demonstrated that the increase in bone width at the crestal area, specifically at the site of cortical discs, ranged from a minimum of 2.03 mm to a maximum of 5.76 mm. Moreover, the initial bone width before reconstruction in the evaluated cases ranged from a minimum of 1.74 mm to a maximum of 4.40 mm. Radiographs before and after the procedure indicated a noteworthy bone formation. Conclusions The findings suggest that employing a single screw to secure the cortical disc while connecting it to the disc outside of the patient's oral cavity can facilitate the surgical process and enhance patient comfort.

CureusVol. 17(6)
Kerman University of Medical Sciences (IR), Karl Bremer Hospital (ZA), Babol University of Medical Sciences (IR)
Openalex Percentile: Top 80%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.