RevCore thrombectomy device effectively restores venous stent patency by treating iliofemoral caval in-stent restenosis

Experience with the RevCore mechanical thrombectomy device in a series of 40 patients is described. The device was employed in the treatment of symptomatic in-stent restenosis (ISR) in iliofemoral caval venous stents in these patients. Computed tomography venography was performed preoperatively to differentiate ISR from stent compression in all patients who underwent intervention. All patients were treated in a single session with a mean estimated blood loss of <10 mL with an average operative time of <30 minutes. Alteplase was not used in any patient. All patients were discharged home the same day. Resolution of ≥50% ISR at the end of the procedure on intravascular ultrasound examination was noted in all patients. Symptom resolution was noted in all patients after the use of the RevCore device. No clinical perioperative pulmonary embolism was observed. Only one patient (2.5%) required reintervention during the follow-up period (range, 2-24 months).

Authors

Institutions

Publication Details

Journal
Journal of Vascular Surgery Cases and Innovative Techniques
Published
2025-06-21
DOI
https://doi.org/10.1016/j.jvscit.2025.101893
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RevCore thrombectomy device effectively restores venous stent patency by treating iliofemoral caval in-stent restenosis

Taimur Saleem, Seshadri Raju
Journal of Vascular Surgery Cases and Innovative Techniques
Venous Thromboembolism Diagnosis and Management
article

RevCore thrombectomy device effectively restores venous stent patency by treating iliofemoral caval in-stent restenosis

Taimur Saleem, Seshadri Raju
article en

Abstract

Experience with the RevCore mechanical thrombectomy device in a series of 40 patients is described. The device was employed in the treatment of symptomatic in-stent restenosis (ISR) in iliofemoral caval venous stents in these patients. Computed tomography venography was performed preoperatively to differentiate ISR from stent compression in all patients who underwent intervention. All patients were treated in a single session with a mean estimated blood loss of <10 mL with an average operative time of <30 minutes. Alteplase was not used in any patient. All patients were discharged home the same day. Resolution of ≥50% ISR at the end of the procedure on intravascular ultrasound examination was noted in all patients. Symptom resolution was noted in all patients after the use of the RevCore device. No clinical perioperative pulmonary embolism was observed. Only one patient (2.5%) required reintervention during the follow-up period (range, 2-24 months).

Journal of Vascular Surgery Cases and Innovative TechniquesVol. 11(5)
Mississippi Sports Medicine and Orthopaedic Center (US)
Zero hunger
Openalex Percentile: Top 71%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

RevCore thrombectomy device effectively restores venous stent patency by treating iliofemoral caval in-stent restenosis — Taimur Saleem, Seshadri Raju · Journal of Vascular Surgery Cases and Innovative Techniques (2025) | TGRS Research Map | TGRS