The Power Transmission Losses: Kajaki to Kandahar Breshna Kot

In this comprehensive study, we investigated the significant voltage drop observed in the 110 kV high-voltage transmission line connecting the Kajaki Hydroelectric Power Plant to the Kandahar Brishna Kot substation, spanning 171 km. The drop is mainly due to the line’s extended length and its resistive and reactive characteristics. Using both quantitative and qualitative methods, supported by ETAP software and data from Da Afghanistan Breshna Sherkat (DABS), the analysis revealed that the voltage drop exceeds the International Electrotechnical Commission (IEC) standards, resulting in significant power losses. To mitigate this issue, the study recommends upgrading the voltage level from 110 kV to 220 kV. This enhancement would reduce current, minimize resistive losses, and improve efficiency by increasing the conductor's cross-sectional area and reorganizing the transmission route with standard components. Implementing these measures is projected to significantly decrease power losses and enhance the overall reliability and performance of the regional power transmission system.

Authors

Institutions

Publication Details

Journal
Journal of Natural Sciences – Kabul University
Published
2025-06-21
DOI
https://doi.org/10.62810/jns.v8i1.78
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Power Transmission Losses: Kajaki to Kandahar Breshna Kot

Mohammad Sharifi, Qais Ahmad Rahimi
Journal of Natural Sciences – Kabul University
Optimal Power Flow Distribution
article

The Power Transmission Losses: Kajaki to Kandahar Breshna Kot

Mohammad Sharifi, Qais Ahmad Rahimi
article en

Abstract

In this comprehensive study, we investigated the significant voltage drop observed in the 110 kV high-voltage transmission line connecting the Kajaki Hydroelectric Power Plant to the Kandahar Brishna Kot substation, spanning 171 km. The drop is mainly due to the line’s extended length and its resistive and reactive characteristics. Using both quantitative and qualitative methods, supported by ETAP software and data from Da Afghanistan Breshna Sherkat (DABS), the analysis revealed that the voltage drop exceeds the International Electrotechnical Commission (IEC) standards, resulting in significant power losses. To mitigate this issue, the study recommends upgrading the voltage level from 110 kV to 220 kV. This enhancement would reduce current, minimize resistive losses, and improve efficiency by increasing the conductor's cross-sectional area and reorganizing the transmission route with standard components. Implementing these measures is projected to significantly decrease power losses and enhance the overall reliability and performance of the regional power transmission system.

Journal of Natural Sciences – Kabul UniversityVol. 8(1)
Kabul University (AF)
Affordable and clean energy
Openalex Percentile: Top 88%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.