Coil for Microscale Imaging

The aim of this work was to design a coil for magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) to analyze the morphology of cells in vitro. This newly developed hardware, due to compatibility to the 1.5-Tesla MRI scanner (GE Healthcare, Boston, MA, USA), allows for the characterization of cell cultures in vitro. To adapt a designed coil on the 1.5-Tesla MRI scanner, some changes in hardware and software were carried out. The advantage of the designed receiving circuit is the ability to perform MRI with a resolution of 80 μm × 80 μm pixel size. Additionally, this coil can be used to visualize cell cultures and tissue sections, which, due to their small dimensions, could not be imaged on standard MRS and MRI coils at 1.5 Tesla.

Authors

Institutions

Publication Details

Journal
Hardware
Published
2025-06-20
DOI
https://doi.org/10.3390/hardware3030006
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coil for Microscale Imaging

David Aebisher, Adrian Truszkiewicz, Dorota Bartusik‐Aebisher
Hardware
Advanced MRI Techniques and Applications
article

Coil for Microscale Imaging

David Aebisher, Adrian Truszkiewicz, Dorota Bartusik‐Aebisher
article en

Abstract

The aim of this work was to design a coil for magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) to analyze the morphology of cells in vitro. This newly developed hardware, due to compatibility to the 1.5-Tesla MRI scanner (GE Healthcare, Boston, MA, USA), allows for the characterization of cell cultures in vitro. To adapt a designed coil on the 1.5-Tesla MRI scanner, some changes in hardware and software were carried out. The advantage of the designed receiving circuit is the ability to perform MRI with a resolution of 80 μm × 80 μm pixel size. Additionally, this coil can be used to visualize cell cultures and tissue sections, which, due to their small dimensions, could not be imaged on standard MRS and MRI coils at 1.5 Tesla.

HardwareVol. 3(3)
University of Rzeszów (PL)
Openalex Percentile: Top 78%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.