Electrical equivalent circuit for analyzing the effect of signal shape on power distribution in cochlear implant electrodes and surrounding tissue

Cochlear implants are a well-established solution for restoring hearing in severe impairment and profound deafness. However, cochlear implants still have limitations, such as speech recognition in noisy environments caused by intra-cochlear current spread across different auditory spiral ganglion neurons as a consequence of, e.g., the large distance of the stimulation electrodes to the target cells in a highly conductive environment. Stimulation in cochlear implants is typically done with charge balanced biphasic rectangular current pulses in a monopolar arrangement. However, several studies have shown that a rectangular stimulation pulse is not optimal for stimulating spiral ganglion neurons. For example, stimulation with a ramped pulse, such as a sawtooth pulse, has been shown to be more energy-efficient and achieves a similar threshold profile in spiral ganglion neurons. In this study, a new but simple equivalent electrical circuit model is introduced that describes the complex impedance between two stimulation electrodes of a cochlear implant with high accuracy (mean relative error ≤ 8%). Based on this bipolar model, a monopolar equivalent electrical circuit model is developed to describe the stimulation between one stimulation electrode and a counter electrode located outside the cochlea. These two models now allow for analyzing the effect of stimulation pulse shape on power distribution in cochlear implant electrodes and surrounding tissue providing a tool for investigating stimulation efficiency with respect to energy losses in the cochlear implant electrode.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-06-20
DOI
https://doi.org/10.1038/s41598-025-04840-5
Citations
1
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical equivalent circuit for analyzing the effect of signal shape on power distribution in cochlear implant electrodes and surrounding tissue

Mit Balvantray Bhavsar, Hans Jürgen Maier, Merle Sehlmeyer, Andrej Kral et al.
1 citations
Scientific Reports
Hearing Loss and Rehabilitation
1.43
article

Electrical equivalent circuit for analyzing the effect of signal shape on power distribution in cochlear implant electrodes and surrounding tissue

Mit Balvantray Bhavsar, Hans Jürgen Maier, Merle Sehlmeyer, Andrej Kral, Stefan Zimmermann, Maksim Makarenko, H. Maier, Tatiana Blank, Nele Schoerner
article en
1 citations

Abstract

Cochlear implants are a well-established solution for restoring hearing in severe impairment and profound deafness. However, cochlear implants still have limitations, such as speech recognition in noisy environments caused by intra-cochlear current spread across different auditory spiral ganglion neurons as a consequence of, e.g., the large distance of the stimulation electrodes to the target cells in a highly conductive environment. Stimulation in cochlear implants is typically done with charge balanced biphasic rectangular current pulses in a monopolar arrangement. However, several studies have shown that a rectangular stimulation pulse is not optimal for stimulating spiral ganglion neurons. For example, stimulation with a ramped pulse, such as a sawtooth pulse, has been shown to be more energy-efficient and achieves a similar threshold profile in spiral ganglion neurons. In this study, a new but simple equivalent electrical circuit model is introduced that describes the complex impedance between two stimulation electrodes of a cochlear implant with high accuracy (mean relative error ≤ 8%). Based on this bipolar model, a monopolar equivalent electrical circuit model is developed to describe the stimulation between one stimulation electrode and a counter electrode located outside the cochlea. These two models now allow for analyzing the effect of stimulation pulse shape on power distribution in cochlear implant electrodes and surrounding tissue providing a tool for investigating stimulation efficiency with respect to energy losses in the cochlear implant electrode.

Scientific ReportsVol. 15(1)
Leibniz University Hannover (DE), Medizinische Hochschule Hannover (DE)
Gottfried Wilhelm Leibniz Universität Hannover
Affordable and clean energy
Openalex Percentile: Top 18%
Hearing Loss and Rehabilitation
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.