Levodopa Sensing with a Nanosensor Array via a Low-Cost Near Infrared Readout

Near infrared (NIR) signals are beneficial for biomedical applications due to reduced light absorption, scattering, and autofluorescence in this range, which promises higher signal-to-noise ratios (SNR). Single-walled carbon nanotubes (SWCNTs) fluoresce in the NIR (800-1700 nm) and serve as building blocks for biosensors. To quantify the benefits of NIR fluorescence biosensing, we simulate the SNR considering wavelength-dependent scattering/absorption, autofluorescence, dark currents, and excitation background. We also compare Si and InGaAs PIN phototdiodes (pn diode with an additional intrinsic layer) as detectors for the NIR region. The simulation shows that the SNR of fluorophores in the NIR is higher, but InGaAs detectors are outperformed by Si detectors in the short NIR (<1050 nm). This was also validated in experiments with (6,5)-SWCNTs (emission 990 nm), showing a 1.2-fold higher SNR for Si PIN photodiodes. Next, SWCNTs were chemically modified to create sensor arrays/barcodes that detect levodopa. Monitoring levodopa blood levels is a crucial step for personalized Parkinson's disease treatment. We then combine nanosensors and detectors to engineer a portable low-cost fluorescence reader that scans (6,5)-SWCNT sensor barcodes. It detects levodopa at relevant concentrations (10 μM) in human blood serum. Thus, we combine NIR fluorescent sensors with high SNR and low-cost Si detectors to make use of beneficial NIR signals, which opens opportunities for point-of-care applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-20
DOI
https://doi.org/10.1021/acs.analchem.5c02320
Citations
4
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
3.22

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Levodopa Sensing with a Nanosensor Array via a Low-Cost Near Infrared Readout

Julia Ackermann, Markus Gregor, Sebastian Kruss, Mathias Augustin et al.
4 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
3.22
article

Levodopa Sensing with a Nanosensor Array via a Low-Cost Near Infrared Readout

Julia Ackermann, Markus Gregor, Sebastian Kruss, Mathias Augustin, Jan Stegemann, Krisztian Neutsch, Svenja Herbertz, Nour el Houda Fizzi
article en
4 citations

Abstract

Near infrared (NIR) signals are beneficial for biomedical applications due to reduced light absorption, scattering, and autofluorescence in this range, which promises higher signal-to-noise ratios (SNR). Single-walled carbon nanotubes (SWCNTs) fluoresce in the NIR (800-1700 nm) and serve as building blocks for biosensors. To quantify the benefits of NIR fluorescence biosensing, we simulate the SNR considering wavelength-dependent scattering/absorption, autofluorescence, dark currents, and excitation background. We also compare Si and InGaAs PIN phototdiodes (pn diode with an additional intrinsic layer) as detectors for the NIR region. The simulation shows that the SNR of fluorophores in the NIR is higher, but InGaAs detectors are outperformed by Si detectors in the short NIR (<1050 nm). This was also validated in experiments with (6,5)-SWCNTs (emission 990 nm), showing a 1.2-fold higher SNR for Si PIN photodiodes. Next, SWCNTs were chemically modified to create sensor arrays/barcodes that detect levodopa. Monitoring levodopa blood levels is a crucial step for personalized Parkinson's disease treatment. We then combine nanosensors and detectors to engineer a portable low-cost fluorescence reader that scans (6,5)-SWCNT sensor barcodes. It detects levodopa at relevant concentrations (10 μM) in human blood serum. Thus, we combine NIR fluorescent sensors with high SNR and low-cost Si detectors to make use of beneficial NIR signals, which opens opportunities for point-of-care applications.

Analytical ChemistryVol. 97(25)
Fraunhofer Institute for Microelectronic Circuits and Systems (DE), FH Münster University of Applied Sciences (DE), Ruhr University Bochum (DE)
Deutsche Forschungsgemeinschaft, Volkswagen Foundation, Bundesministerium für Bildung und Forschung, Fraunhofer-Gesellschaft, Ministerium für Kultur und Wissenschaft des Landes Nordrhein-Westfalen
Affordable and clean energy
Openalex Percentile: Top 8%
Advanced biosensing and bioanalysis techniques
3.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.