One-pot assembling pyrroloquinoline quinone glucose dehydrogenase with polydopamine to overcome the reproducibility issues of layer-by-layer electrode development

The reproducibility of enzyme-based biosensors remains a critical challenge, particularly in clinical and wearable applications. Here, we present a novel one-pot polydopamine (PDA)-assisted immobilization strategy for pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH) on graphite electrodes to address the limitations of conventional layer-by-layer (LbL) methods. The (PQQ-GDH/PDA)<sub>OPA</sub>/G platform demonstrated a uniform and nanostructured enzyme-polymer matrix, confirmed by SEM and spectroscopic characterization, resulting in enhanced surface coverage and enzyme stabilization. Electrochemical analyses revealed an onset potential of +0.19 ± 0.01 V and a maximum current of 0.87 ± 0.08 μA in the presence of glucose. Amperometric calibration yielded a linear range of 0.4-1.2 mM, a sensitivity of 0.47 μA mM<sup>-1</sup>, and a low detection limit of 26 ± 2 μM. Michaelis-Menten kinetic analysis provided an <i>I</i> <sub>max</sub> of 1.13 ± 0.07 μA and a <i>K</i> <sup>app</sup> <sub>M</sub> of 3.11 ± 0.59 mM. Reproducibility was excellent, with relative standard deviations below 8% for all key parameters. The biosensor retained full functionality under physiological conditions (pH 7.2, 37 °C) and exhibited high selectivity against common interferents, including dopamine, uric acid, and ascorbic acid, with signal variations below 5%. Remarkably, the sensor maintained stable responses in artificial serum for over 67 days, confirming its long-term operational stability. These findings highlight the one-pot PDA-based approach as a scalable, reproducible, and biocompatible platform for next-generation glucose biosensors suitable for real-world biomedical monitoring.

Authors

Institutions

Publication Details

Journal
Sensors & Diagnostics
Published
2025-01-01
DOI
https://doi.org/10.1039/d5sd00053j
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-pot assembling pyrroloquinoline quinone glucose dehydrogenase with polydopamine to overcome the reproducibility issues of layer-by-layer electrode development

Luisa Torsi, Angela Stefanachi, Eleonora Macchia, Alessandra Cimino et al.
3 citations
Sensors & Diagnostics
Electrochemical sensors and biosensors
2.19
article

One-pot assembling pyrroloquinoline quinone glucose dehydrogenase with polydopamine to overcome the reproducibility issues of layer-by-layer electrode development

Luisa Torsi, Angela Stefanachi, Eleonora Macchia, Alessandra Cimino, Shixin Wang, Angelo Tricase, Verdiana Marchianò, Paolo Bollella, Xiaoming Zhang, Blanca Cassano
article en
3 citations

Abstract

The reproducibility of enzyme-based biosensors remains a critical challenge, particularly in clinical and wearable applications. Here, we present a novel one-pot polydopamine (PDA)-assisted immobilization strategy for pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH) on graphite electrodes to address the limitations of conventional layer-by-layer (LbL) methods. The (PQQ-GDH/PDA)<sub>OPA</sub>/G platform demonstrated a uniform and nanostructured enzyme-polymer matrix, confirmed by SEM and spectroscopic characterization, resulting in enhanced surface coverage and enzyme stabilization. Electrochemical analyses revealed an onset potential of +0.19 ± 0.01 V and a maximum current of 0.87 ± 0.08 μA in the presence of glucose. Amperometric calibration yielded a linear range of 0.4-1.2 mM, a sensitivity of 0.47 μA mM<sup>-1</sup>, and a low detection limit of 26 ± 2 μM. Michaelis-Menten kinetic analysis provided an <i>I</i> <sub>max</sub> of 1.13 ± 0.07 μA and a <i>K</i> <sup>app</sup> <sub>M</sub> of 3.11 ± 0.59 mM. Reproducibility was excellent, with relative standard deviations below 8% for all key parameters. The biosensor retained full functionality under physiological conditions (pH 7.2, 37 °C) and exhibited high selectivity against common interferents, including dopamine, uric acid, and ascorbic acid, with signal variations below 5%. Remarkably, the sensor maintained stable responses in artificial serum for over 67 days, confirming its long-term operational stability. These findings highlight the one-pot PDA-based approach as a scalable, reproducible, and biocompatible platform for next-generation glucose biosensors suitable for real-world biomedical monitoring.

Sensors & DiagnosticsVol. 4(9)
Åbo Akademi University (FI), Minzu University of China (CN), University of Bari Aldo Moro (IT)
Ministero della Salute, Universita degli Studi di Bari Aldo Moro, Regione Puglia, Minzu University of China, European Research Council
Openalex Percentile: Top 12%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.