Optimal cubic nonlinear damping for seismic inter-story vibration isolation under critical double and multiple impulse inputs

Power-law nonlinear damping has been shown to be able to reduce the seismic responses of building structures over a broad range of frequencies.Many studies have been reported on the design of additional power law damping for the purpose of inter-story vibration isolation.The double and multiple impulse inputs were proposed to represent the near-fault and harmonic ground motions, respectively to facilitate a straightforward evaluation of the critical and resonant responses of elastic-plastic building systems to earthquake ground motions.In this study, a three-degree-of-freedom (3-dof) building system with a cubic nonlinear damper fitted on the second floor is considered.The nonlinear critical responses of this system to double and multiple impulse inputs with different amplitude levels are evaluated for the optimal design of the coefficient of the additional cubic damping.The optimal design is conducted based on the concept of Output Frequency Response Function (OFRF), which was derived by the frequency domain analysis of nonlinear systems and, in this study, allows the building response to the critical input to be represented as an explicit function of the damping coefficient to be designed.The objectives are to reduce the inter-story drift of each floor, the acceleration of the top floor, as well as the total vibration energy in critical cases of earthquake ground motions.The critical double and multiple impulse inputs have been defined as the inputs that can maximize the energy input into the system with their critical timing proven to be the timing when the sum of the inertial force of each floor becomes zero.The effectiveness of the optimally designed cubic damping is demonstrated using both recorded and simulated earthquake ground motions.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.23967/icossar.2025.056
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal cubic nonlinear damping for seismic inter-story vibration isolation under critical double and multiple impulse inputs

Yu Zhu, Kazuyuki Kojima, Zi–Qiang Lang
1 links
Vibration and Dynamic Analysis
article

Optimal cubic nonlinear damping for seismic inter-story vibration isolation under critical double and multiple impulse inputs

Yu Zhu, Kazuyuki Kojima, Zi–Qiang Lang
article en

Abstract

Power-law nonlinear damping has been shown to be able to reduce the seismic responses of building structures over a broad range of frequencies.Many studies have been reported on the design of additional power law damping for the purpose of inter-story vibration isolation.The double and multiple impulse inputs were proposed to represent the near-fault and harmonic ground motions, respectively to facilitate a straightforward evaluation of the critical and resonant responses of elastic-plastic building systems to earthquake ground motions.In this study, a three-degree-of-freedom (3-dof) building system with a cubic nonlinear damper fitted on the second floor is considered.The nonlinear critical responses of this system to double and multiple impulse inputs with different amplitude levels are evaluated for the optimal design of the coefficient of the additional cubic damping.The optimal design is conducted based on the concept of Output Frequency Response Function (OFRF), which was derived by the frequency domain analysis of nonlinear systems and, in this study, allows the building response to the critical input to be represented as an explicit function of the damping coefficient to be designed.The objectives are to reduce the inter-story drift of each floor, the acceleration of the top floor, as well as the total vibration energy in critical cases of earthquake ground motions.The critical double and multiple impulse inputs have been defined as the inputs that can maximize the energy input into the system with their critical timing proven to be the timing when the sum of the inertial force of each floor becomes zero.The effectiveness of the optimally designed cubic damping is demonstrated using both recorded and simulated earthquake ground motions.

Japan Society for the Promotion of Science
Sustainable cities and communities, Climate action
Openalex Percentile: Top 84%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimal cubic nonlinear damping for seismic inter-story vibration isolation under critical double and multiple impulse inputs — Yu Zhu, Kazuyuki Kojima, et al. · (2025) | TGRS Research Map | TGRS