Design of FBG‐Based Sensing System for Meat Quality Assessment and Steak Cooking Optimisation

ABSTRACT Water presence in raw meat not only degrades its quality by diluting the natural flavours, but also increases the risk of bacterial growth, altering texture, and juiciness which ultimately affects the quality of end products. Therefore, quality assessment of raw meat in markets as well as in eateries is important to ensure the consumer's safety and satisfaction. In this paper, we propose a nondestructive technique to detect water presence in raw meat and steak cooking temperature optimisation using a fibre Bragg grating (FBG) temperature sensor inserted into the piece of raw meat. The contribution of this paper is twofold: First, the water presence in the piece of raw meat is detected by analysing the shift in Bragg wavelength corresponding to time‐dependent gradual decrease in temperature of heated probe of FBG sensor due to convective heat transfer from probe to meat. Secondly, the optimum cooking temperature of a particular type of steak is achieved after quality assessment of meat by analysing the shift in Bragg wavelength corresponding to time‐dependent gradual increase in probe temperature due to convective heat transfer from meat to probe. The results show that the proposed sensing system can complete the error‐free detection of water in 250 g piece of raw meat within 30 s for water contents of 50, 75, and 100 g which account for 20%, 30%, and 40% of the net weight of meat, respectively. Moreover, the simulated and experimental values of temperature sensitivity (TS) of FBG sensor used in this work are around 13 and 10 pm/°C, respectively. The proof of the concept of a smart restaurant based upon the proposed work is also discussed. This study provides a nondestructive, simple, and fast solution for detection of water in raw meat and achieving the optimum cooking temperature for different types of steaks.

Authors

Institutions

Publication Details

Journal
IET Optoelectronics
Published
2025-01-01
DOI
https://doi.org/10.1049/ote2.70006
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of FBG‐Based Sensing System for Meat Quality Assessment and Steak Cooking Optimisation

Ahmad Atieh, Jawad Mirza, Anwar Ul Haq, Benish Kanwal et al.
IET Optoelectronics
Advanced Fiber Optic Sensors
article

Design of FBG‐Based Sensing System for Meat Quality Assessment and Steak Cooking Optimisation

Ahmad Atieh, Jawad Mirza, Anwar Ul Haq, Benish Kanwal, Salman Ghafoor, Firdos Kanwal, Ahmad Almogren, Muhammad Ijaz
article en

Abstract

ABSTRACT Water presence in raw meat not only degrades its quality by diluting the natural flavours, but also increases the risk of bacterial growth, altering texture, and juiciness which ultimately affects the quality of end products. Therefore, quality assessment of raw meat in markets as well as in eateries is important to ensure the consumer's safety and satisfaction. In this paper, we propose a nondestructive technique to detect water presence in raw meat and steak cooking temperature optimisation using a fibre Bragg grating (FBG) temperature sensor inserted into the piece of raw meat. The contribution of this paper is twofold: First, the water presence in the piece of raw meat is detected by analysing the shift in Bragg wavelength corresponding to time‐dependent gradual decrease in temperature of heated probe of FBG sensor due to convective heat transfer from probe to meat. Secondly, the optimum cooking temperature of a particular type of steak is achieved after quality assessment of meat by analysing the shift in Bragg wavelength corresponding to time‐dependent gradual increase in probe temperature due to convective heat transfer from meat to probe. The results show that the proposed sensing system can complete the error‐free detection of water in 250 g piece of raw meat within 30 s for water contents of 50, 75, and 100 g which account for 20%, 30%, and 40% of the net weight of meat, respectively. Moreover, the simulated and experimental values of temperature sensitivity (TS) of FBG sensor used in this work are around 13 and 10 pm/°C, respectively. The proof of the concept of a smart restaurant based upon the proposed work is also discussed. This study provides a nondestructive, simple, and fast solution for detection of water in raw meat and achieving the optimum cooking temperature for different types of steaks.

IET OptoelectronicsVol. 19(1)
Manchester Metropolitan University (GB), King Saud University (SA), HITEC University (PK), Optiwave Systems (Canada) (CA), Mirpur University of Science and Technology (PK), National University of Sciences and Technology (PK)
King Saud University
Clean water and sanitation
Openalex Percentile: Top 88%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.