Investigation on performance of deep borehole heat exchanger heating system coupled air source heat pump with different allocation ratios

The coupled heating system of deep geothermal heat pumps and air-source heat pumps has received extensive attention due to the complementary advantages of the two clean energy sources. However, in the coupled system, the load proportions borne by the geothermal part and the air-source part need to be reasonably designed. This study is based on buildings that use the geothermal heat pump coupled with an air source heat pump system for heating. The dynamic thermal load of the buildings is simulated using DEST, and five different load allocation ratios from 0.5 to 0.9 (the proportion of load borne by the geothermal heat pump) are given. The long-term operation parameters of the geothermal heat pump system are simulated using OpenGeoSys, and the variation laws of power consumption and total cost during the long-term operation of the coupled system are obtained. In summary, the load allocation ratio of the geothermal part should be above 0.7 to achieve the optimal balance between economy and energy conservation.

Authors

Institutions

Publication Details

Published
2025-04-11
DOI
https://doi.org/10.1109/icgeps65133.2025.11034516
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on performance of deep borehole heat exchanger heating system coupled air source heat pump with different allocation ratios

Yong Zhang, Pengfei Zhang, Chunmiao Wang, Jing Wang et al.
Geothermal Energy Systems and Applications
article

Investigation on performance of deep borehole heat exchanger heating system coupled air source heat pump with different allocation ratios

Yong Zhang, Pengfei Zhang, Chunmiao Wang, Jing Wang, Zhihua Wang, Jia Yuan, Saisai Du, Xuan Liu
article en

Abstract

The coupled heating system of deep geothermal heat pumps and air-source heat pumps has received extensive attention due to the complementary advantages of the two clean energy sources. However, in the coupled system, the load proportions borne by the geothermal part and the air-source part need to be reasonably designed. This study is based on buildings that use the geothermal heat pump coupled with an air source heat pump system for heating. The dynamic thermal load of the buildings is simulated using DEST, and five different load allocation ratios from 0.5 to 0.9 (the proportion of load borne by the geothermal heat pump) are given. The long-term operation parameters of the geothermal heat pump system are simulated using OpenGeoSys, and the variation laws of power consumption and total cost during the long-term operation of the coupled system are obtained. In summary, the load allocation ratio of the geothermal part should be above 0.7 to achieve the optimal balance between economy and energy conservation.

PowerChina (China) (CN), China Power Engineering Consulting Group (China) (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 91%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.