One-Port Quality Factor Measurement of High-Q Mems Gyroscope Utilizing Negative Impedance Converter

We propose a novel Q-factor measurement method utilizing a negative impedance converter (NIC) in the MEMS gyros for the first time. It can be regarded as a variant of the commonly used closed-loop counterpart but with only one mandatory port. It facilitates a more reliable Q-factor measurement of the sense resonator in an open-loop MEMS gyro, where the force electrode is unavailable. Its build-up time can be shortened to 0.16s with a Q-factor of 15.4k by increasing the value of negative impedance. Alternatively, the build-up time can also be improved by adding noise excitation during its drive phase. This approach also applies to the drive resonator, and two pairs of drive and detection caps can both be utilized to provide 2x extra gain factor.

Authors

Institutions

Publication Details

Published
2025-05-04
DOI
https://doi.org/10.1109/inertial63280.2025.11037197
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Port Quality Factor Measurement of High-Q Mems Gyroscope Utilizing Negative Impedance Converter

Anping Qiu, Jinyang Huang, Meijia Xu, Yang Zhao et al.
Acoustic Wave Resonator Technologies
article

One-Port Quality Factor Measurement of High-Q Mems Gyroscope Utilizing Negative Impedance Converter

Anping Qiu, Jinyang Huang, Meijia Xu, Yang Zhao, Guoming Xia, Qin Shi
article en

Abstract

We propose a novel Q-factor measurement method utilizing a negative impedance converter (NIC) in the MEMS gyros for the first time. It can be regarded as a variant of the commonly used closed-loop counterpart but with only one mandatory port. It facilitates a more reliable Q-factor measurement of the sense resonator in an open-loop MEMS gyro, where the force electrode is unavailable. Its build-up time can be shortened to 0.16s with a Q-factor of 15.4k by increasing the value of negative impedance. Alternatively, the build-up time can also be improved by adding noise excitation during its drive phase. This approach also applies to the drive resonator, and two pairs of drive and detection caps can both be utilized to provide 2x extra gain factor.

Nanjing University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

One-Port Quality Factor Measurement of High-Q Mems Gyroscope Utilizing Negative Impedance Converter — Anping Qiu, Jinyang Huang, et al. · (2025) | TGRS Research Map | TGRS