An Injected Impedance Measurement Based on Noninjected a Priori Results

In recent years, the deepening of China’s energy system reform has led to an increasingly severe problem of harmonic pollution, exacerbated by the integration of highpenetration power electronic devices and nonlinear loads. To tackle this challenge, this research proposes a novel dual-channel impedance measurement method that incorporates mutual correction. The methodology involves a two-stage measurement process. Initially, a non-injected method is employed to obtain a preliminary estimate of the harmonic impedance on the system side. Subsequently, an injection method is applied for precise measurement and mutual correction of specific harmonics. Simulation results validate the effectiveness of the proposed method in enhancing the accuracy of impedance measurements.

Authors

Institutions

Publication Details

Published
2025-04-11
DOI
https://doi.org/10.1109/icgeps65133.2025.11034591
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Injected Impedance Measurement Based on Noninjected a Priori Results

Yang Liu, Qian Zhao, Bing Shen, Hao Chen et al.
Electrical and Bioimpedance Tomography
article

An Injected Impedance Measurement Based on Noninjected a Priori Results

Yang Liu, Qian Zhao, Bing Shen, Hao Chen, Peng Zhang, Ying Wang
article en

Abstract

In recent years, the deepening of China’s energy system reform has led to an increasingly severe problem of harmonic pollution, exacerbated by the integration of highpenetration power electronic devices and nonlinear loads. To tackle this challenge, this research proposes a novel dual-channel impedance measurement method that incorporates mutual correction. The methodology involves a two-stage measurement process. Initially, a non-injected method is employed to obtain a preliminary estimate of the harmonic impedance on the system side. Subsequently, an injection method is applied for precise measurement and mutual correction of specific harmonics. Simulation results validate the effectiveness of the proposed method in enhancing the accuracy of impedance measurements.

State Grid Corporation of China (China) (CN), Sichuan University (CN), Shanghai Electric (China) (CN)
State Grid Corporation of China
Openalex Percentile: Top 88%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Injected Impedance Measurement Based on Noninjected a Priori Results — Yang Liu, Qian Zhao, et al. · (2025) | TGRS Research Map | TGRS