Scale Factor Nonlinearity Suppression in Micromachined Resonant Accelerometers by Using an Improved Proportion F-Squared Method

In this paper, an improved proportion f-squared method (PFS) is proposed for the first time to reduce the nonlinearity error of scale factor in micro-machined resonant accelerometers (MRAs). The precision centrifuge test is firstly conducted to recognize the polynomial fitting model for further determination of a proportion factor, which can help achieve better cancelation of nonlinearity error, especially the quadratic residual error caused by imperfect symmetry of two resonators. The experiment results demonstrate a remarkable 50% decrease in the scale factor nonlinearity error, from over 23ppm to 12.5ppm within a ±20g measurement range, alongside improved linearity symmetry in both tests under the positive and negative input accelerations.

Authors

Institutions

Publication Details

Published
2025-05-04
DOI
https://doi.org/10.1109/inertial63280.2025.11036933
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scale Factor Nonlinearity Suppression in Micromachined Resonant Accelerometers by Using an Improved Proportion F-Squared Method

Haonan Li, Rong Zhang, Fengtian Han, Yukun Ma
Advanced MEMS and NEMS Technologies
article

Scale Factor Nonlinearity Suppression in Micromachined Resonant Accelerometers by Using an Improved Proportion F-Squared Method

Haonan Li, Rong Zhang, Fengtian Han, Yukun Ma
article en

Abstract

In this paper, an improved proportion f-squared method (PFS) is proposed for the first time to reduce the nonlinearity error of scale factor in micro-machined resonant accelerometers (MRAs). The precision centrifuge test is firstly conducted to recognize the polynomial fitting model for further determination of a proportion factor, which can help achieve better cancelation of nonlinearity error, especially the quadratic residual error caused by imperfect symmetry of two resonators. The experiment results demonstrate a remarkable 50% decrease in the scale factor nonlinearity error, from over 23ppm to 12.5ppm within a ±20g measurement range, alongside improved linearity symmetry in both tests under the positive and negative input accelerations.

Tsinghua University (CN)
National Science Foundation
Openalex Percentile: Top 88%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.