Scale Factor Nonlinearity Suppression in Micromachined Resonant Accelerometers by Using an Improved Proportion F-Squared Method
In this paper, an improved proportion f-squared method (PFS) is proposed for the first time to reduce the nonlinearity error of scale factor in micro-machined resonant accelerometers (MRAs). The precision centrifuge test is firstly conducted to recognize the polynomial fitting model for further determination of a proportion factor, which can help achieve better cancelation of nonlinearity error, especially the quadratic residual error caused by imperfect symmetry of two resonators. The experiment results demonstrate a remarkable 50% decrease in the scale factor nonlinearity error, from over 23ppm to 12.5ppm within a ±20g measurement range, alongside improved linearity symmetry in both tests under the positive and negative input accelerations.
Authors
- Haonan Li
- Rong Zhang (ORCID: https://orcid.org/0000-0002-9872-2954)
- Fengtian Han (ORCID: https://orcid.org/0000-0001-8425-6764)
- Yukun Ma (ORCID: https://orcid.org/0009-0002-4442-7367)
Institutions
- Tsinghua University (CN)
Publication Details
- Published
- 2025-05-04
- DOI
- https://doi.org/10.1109/inertial63280.2025.11036933
- Primary Topic
- Advanced MEMS and NEMS Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Science Foundation