Research on Partial Discharge Detection of a 500kV Step-Up Transformer

In response to the abnormal chromatographic analysis of insulating oil in a 500kV step-up transformer at a power plant, this paper conducts a study on partial discharge (PD) detection. First, the winding and core structure of the step-up transformer were analyzed. Combined with chromatographic monitoring data, it was found that the total hydrocarbon content continued to increase during long-term operation, and the acetylene content was abnormal, indicating potential risks of medium- and low-temperature overheating and partial discharge. Using high-frequency current transformer (HFCT) technology, high-frequency current detection was performed on the core, clamps, and grounding points of phases A, B, and C of the main transformer. Typical Phase-Resolved Partial Discharge (PRPD) patterns were obtained, clarifying the characteristics and magnitude of the discharge signals. The study results indicate the presence of multi-point discharge phenomena inside the step-up transformer, with differences in discharge intensity across phases. Finally, based on the detection results, this paper proposes improvement measures, including enhancing online monitoring, optimizing the operating environment, and conducting in-depth fault analysis, providing a solid foundation for improving the safety and reliability of the step-up transformer.

Authors

Institutions

Publication Details

Published
2025-04-11
DOI
https://doi.org/10.1109/icgeps65133.2025.11034510
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Partial Discharge Detection of a 500kV Step-Up Transformer

Chuanbo Xu
High voltage insulation and dielectric phenomena
article

Research on Partial Discharge Detection of a 500kV Step-Up Transformer

Chuanbo Xu
article en

Abstract

In response to the abnormal chromatographic analysis of insulating oil in a 500kV step-up transformer at a power plant, this paper conducts a study on partial discharge (PD) detection. First, the winding and core structure of the step-up transformer were analyzed. Combined with chromatographic monitoring data, it was found that the total hydrocarbon content continued to increase during long-term operation, and the acetylene content was abnormal, indicating potential risks of medium- and low-temperature overheating and partial discharge. Using high-frequency current transformer (HFCT) technology, high-frequency current detection was performed on the core, clamps, and grounding points of phases A, B, and C of the main transformer. Typical Phase-Resolved Partial Discharge (PRPD) patterns were obtained, clarifying the characteristics and magnitude of the discharge signals. The study results indicate the presence of multi-point discharge phenomena inside the step-up transformer, with differences in discharge intensity across phases. Finally, based on the detection results, this paper proposes improvement measures, including enhancing online monitoring, optimizing the operating environment, and conducting in-depth fault analysis, providing a solid foundation for improving the safety and reliability of the step-up transformer.

North China Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Partial Discharge Detection of a 500kV Step-Up Transformer — Chuanbo Xu · (2025) | TGRS Research Map | TGRS