Volumetric Criteria and An Automated Assessment Tool Development for Optimizing Building Permeability Design in High-Density Urban Environments

Better urban ventilation can significantly contribute to achieving UN SDGs through better liveability for sustainable cities and communities (SDG 11), better air quality for health and well-being (SDG 3), and more climate-responsive building design for climate action (SDG 13). Aligning with the said goals, a set of guidelines comprising 2-dimensional prescriptive building separation requirements was promulgated by HKSAR's Buildings Department (BD) in 2011 to promote better urban ventilation. However, some practitioners have concerns about applying the guidelines for projects with complex geometries. Projects may adopt alternative assessment methods using wind tunnel or CFD simulations to demonstrate compliance, but the required time and cost are also a concern. Given the concerns and stakeholders’ collective experience using the guidelines, BD commissioned a study in January 2024 to establish an alternative automated assessment tool for cost-effective evaluation of building permeability design using building information modelling (BIM) technologies. A new geometric parametrisation method - Least Cost Path (LCP) was proposed. The method evaluates Friction Cost (FC) and Turning Cost (TC), measuring a building design's airflow resistance and path complexity. These metrics are applied within a 3D assessment grid system for a building project's low, middle and high zones. Normalised CFD and LCP performances were reviewed, showing a strong correlation (R² ~ 0.8). The study also identified a cost threshold under the LCP method that differentiates “good” from “poor” ventilation designs. An automated BIM-integrated assessment tool using the LCP method will be further developed in Phase B of the Study.

Authors

Publication Details

Journal
CIB Conferences
Published
2025-06-19
DOI
https://doi.org/10.7771/3067-4883.2090
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Volumetric Criteria and An Automated Assessment Tool Development for Optimizing Building Permeability Design in High-Density Urban Environments

Man‐kit Leung, Kai Gao, Yueyang He, Cai Yue et al.
CIB Conferences
Hygrothermal properties of building materials
article

Volumetric Criteria and An Automated Assessment Tool Development for Optimizing Building Permeability Design in High-Density Urban Environments

Man‐kit Leung, Kai Gao, Yueyang He, Cai Yue, Edward Ng, Kmy Leung, Yuanhao Zu, Kam Sing Wong, Clement Pang, Jenny Zhao, Tim Huang, Y L Cheung, Dicken Poon
article en

Abstract

Better urban ventilation can significantly contribute to achieving UN SDGs through better liveability for sustainable cities and communities (SDG 11), better air quality for health and well-being (SDG 3), and more climate-responsive building design for climate action (SDG 13). Aligning with the said goals, a set of guidelines comprising 2-dimensional prescriptive building separation requirements was promulgated by HKSAR's Buildings Department (BD) in 2011 to promote better urban ventilation. However, some practitioners have concerns about applying the guidelines for projects with complex geometries. Projects may adopt alternative assessment methods using wind tunnel or CFD simulations to demonstrate compliance, but the required time and cost are also a concern. Given the concerns and stakeholders’ collective experience using the guidelines, BD commissioned a study in January 2024 to establish an alternative automated assessment tool for cost-effective evaluation of building permeability design using building information modelling (BIM) technologies. A new geometric parametrisation method - Least Cost Path (LCP) was proposed. The method evaluates Friction Cost (FC) and Turning Cost (TC), measuring a building design's airflow resistance and path complexity. These metrics are applied within a 3D assessment grid system for a building project's low, middle and high zones. Normalised CFD and LCP performances were reviewed, showing a strong correlation (R² ~ 0.8). The study also identified a cost threshold under the LCP method that differentiates “good” from “poor” ventilation designs. An automated BIM-integrated assessment tool using the LCP method will be further developed in Phase B of the Study.

CIB ConferencesVol. 1(1)
Sustainable cities and communities
Openalex Percentile: Top 85%
Hygrothermal properties of building materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.