Optimized Physiological Monitoring System for COVID-19 Using VLC-Based 3D Localization and Markov Chain Analysis
This research presents an optimized physiological monitoring system for COVID-19 patients, integrating Visible Light Communication (VLC)-based three-dimensional localization with Markov Chain Analysis. The proposed system enables real-time tracking of vital physiological indicators while balancing localization accuracy and computational efficiency, making it suitable for real-world healthcare applications. The VLC-based localization system was implemented using three LED beacons and optimized through Particle Swarm Optimization (PSO). The analysis revealed that optimal PSO parameters (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> = 1.9, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> = 2.1, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">w</i> = 0.8) significantly improved positioning accuracy, with 700 to 1100 particles providing the best trade-off between precision and computational cost. Additionally, the system successfully measured and calibrated cough frequency, respiratory rate, and oxygen saturation (SpO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) using MEMS sensors. The results showed a cough frequency peak at 0.2 Hz, an average respiratory rate of 1.3 breaths per minute, and precise detection of hypoxia events through infrared and red light absorption. To assess disease progression, a Markov Chain Model was developed, analyzing heart rate, temperature, cough frequency, respiratory rate, and SpO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> levels. The model identified four distinct patient states, ranging from mild to severe conditions, and provided probabilistic insights into symptom deterioration. A heat map analysis confirmed the reliability of state transition probabilities. The study underscores the critical trade-off between localization accuracy and computational efficiency, emphasizing the importance of careful parameter selection for real-time medical applications.
Authors
- Eduardo Viera (ORCID: https://orcid.org/0000-0001-5264-1377)
- Carolina Lagos (ORCID: https://orcid.org/0000-0003-4061-8035)
- César A. Azurdia-Meza (ORCID: https://orcid.org/0000-0003-3461-4484)
- Ismael Soto (ORCID: https://orcid.org/0000-0002-5501-5651)
- Raúl Carrasco (ORCID: https://orcid.org/0000-0002-5023-9349)
- Pablo Palacios Játiva (ORCID: https://orcid.org/0000-0002-3958-503X)
- Diego Alonso Candia
- Iván Sánchez (ORCID: https://orcid.org/0000-0003-0686-8612)
Institutions
- Universidad de Santiago de Chile (CL)
- Universidad de Los Andes, Chile (CL)
- Universidad de Las Américas (EC)
- Metropolitan University of Technology (CL)
- University of Chile (CL)
- Universidad Diego Portales (CL)
Publication Details
- Journal
- IEEE Access
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/access.2025.3581790
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Universidad de las Américas Puebla
- Pontificia Universidad Católica del Ecuador
- Fondo Nacional de Desarrollo Científico y Tecnológico