Screw Coating as a Solution to Solve Screw Loosening Complications: An In Vitro Study

<b>Background:</b> This study aimed to evaluate the influence of a screw coating on the screw preload and removal torque value (RTV) with and without the application of a cyclic load (CL) to make screws with greater untightening resistance to prevent screw loosening. <b>Methods</b>: Ninety complexes composed of implants, abutments, and prosthetic screws were examined and tested under CL oral conditions (<i>n =</i> 45) and non-CL conditions (nCL, <i>n =</i> 45). Each group was divided into three subgroups (<i>n</i> = 15): a control group (CG) without a screw coating, a GapSeal<sup>®</sup>-coated screw group (GG), and a polytetrafluoroethylene (PTFE) tape-wrapped screw group (PG). All screws were tightened at 30 Ncm, and the preload was recorded. In the nCL group, the screws were untightened to record the RTV. In the CL group, the screws were tightened, subjected to a CL in distillated water at a temperature of 37 °C, and then untightened to record the RTV. Micro-Ct analysis was conducted on two samples from each group before CL. SEM analyses of two samples per subgroup before and after CL were also performed. <b>Results</b>: The preload in the PG was significantly lower under nCL (29.92 Ncm) compared with CG (30.95 Ncm) and GG (31.19 Ncm) and also under a CL (PG: 30.92 Ncm) compared with CG (31.72 Ncm) and GG (31.42 Ncm). The RTVs of the PG were significantly lower under nCL (15.30 Ncm) compared with CG (27.98 Ncm) and GG (28.46 Ncm). Under CL, the RTVs of the PG were significantly higher (31.50 Ncm) compared with CG (26.00 Ncm) and GG (27.44 Ncm). <b>Conclusions</b>: Wrapping the screw with PTFE tape significantly reduced the preload but resulted in a significantly greater RTV under CL conditions in the simulated oral environment, suggesting that this could be a solution to decrease the risk of screw loosening.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-06-19
DOI
https://doi.org/10.3390/ma18122921
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Screw Coating as a Solution to Solve Screw Loosening Complications: An In Vitro Study

María Cristina Manzanares‐Céspedes, Joana Mendes, José Manuel Mendes, Carlos Aroso et al.
Materials
Orthopaedic implants and arthroplasty
article

Screw Coating as a Solution to Solve Screw Loosening Complications: An In Vitro Study

María Cristina Manzanares‐Céspedes, Joana Mendes, José Manuel Mendes, Carlos Aroso, Lara Coelho
article en

Abstract

<b>Background:</b> This study aimed to evaluate the influence of a screw coating on the screw preload and removal torque value (RTV) with and without the application of a cyclic load (CL) to make screws with greater untightening resistance to prevent screw loosening. <b>Methods</b>: Ninety complexes composed of implants, abutments, and prosthetic screws were examined and tested under CL oral conditions (<i>n =</i> 45) and non-CL conditions (nCL, <i>n =</i> 45). Each group was divided into three subgroups (<i>n</i> = 15): a control group (CG) without a screw coating, a GapSeal<sup>®</sup>-coated screw group (GG), and a polytetrafluoroethylene (PTFE) tape-wrapped screw group (PG). All screws were tightened at 30 Ncm, and the preload was recorded. In the nCL group, the screws were untightened to record the RTV. In the CL group, the screws were tightened, subjected to a CL in distillated water at a temperature of 37 °C, and then untightened to record the RTV. Micro-Ct analysis was conducted on two samples from each group before CL. SEM analyses of two samples per subgroup before and after CL were also performed. <b>Results</b>: The preload in the PG was significantly lower under nCL (29.92 Ncm) compared with CG (30.95 Ncm) and GG (31.19 Ncm) and also under a CL (PG: 30.92 Ncm) compared with CG (31.72 Ncm) and GG (31.42 Ncm). The RTVs of the PG were significantly lower under nCL (15.30 Ncm) compared with CG (27.98 Ncm) and GG (28.46 Ncm). Under CL, the RTVs of the PG were significantly higher (31.50 Ncm) compared with CG (26.00 Ncm) and GG (27.44 Ncm). <b>Conclusions</b>: Wrapping the screw with PTFE tape significantly reduced the preload but resulted in a significantly greater RTV under CL conditions in the simulated oral environment, suggesting that this could be a solution to decrease the risk of screw loosening.

MaterialsVol. 18(12)
Cooperativa de Ensino Superior Politécnico e Universitário (PT), Universitat de Barcelona (ES)
Cooperativa de Ensino Superior Politécnico e Universitário
Clean water and sanitation
Openalex Percentile: Top 76%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.