Predictive value of surface electrocardiogram in localizing right ventricular outflow tract premature beats: a study combining intracardiac echocardiography and electroanatomical mapping under all-zero fluoroscopy ablation
ICE can clearly visualize the anatomical structures of the right ventricular outflow tract, which aids in accurately determining the ablation site. In lead V2, an R wave duration of 50 milliseconds or longer exhibits certain predictive value for ventricular premature beats originating below the pulmonary valve sinus. For PVCs originating below the pulmonary valve, the ablation target sites are primarily concentrated at the junction of the left-anterior pulmonary sinus cusp.
Authors
- Yi Zhang (ORCID: https://orcid.org/0000-0002-2285-0087)
- Jidong Zhang (ORCID: https://orcid.org/0009-0001-1514-2699)
- Ruibin Li (ORCID: https://orcid.org/0009-0005-6108-6615)
- Yichen Li (ORCID: https://orcid.org/0000-0002-9079-104X)
- Xiaoran Cui