Benchmarking Accelerometer and CNN-Based Vision Systems for Sleep Posture Classification in Healthcare Applications

Sleep position recognition plays a crucial role in diagnosing and managing various health conditions, such as sleep apnea, pressure ulcers, and musculoskeletal disorders. Accurate monitoring of body posture during sleep can provide valuable insights for clinicians and support the development of intelligent healthcare systems. This research presents a comparative analysis of sleep position recognition using two distinct approaches: image-based deep learning and accelerometer-based classification. There are five classes: prone, supine, right side, left side, and wake up. For the image-based method, the Visual Geometry Group 16 (VGG16) convolutional neural network was fine-tuned with data augmentation strategies including rotation, reflection, scaling, and translation to enhance model generalization. The image-based model achieved an overall accuracy of 93.49%, with perfect precision and recall for "right side" and "wakeup" positions, but slightly lower performance for "left side" and "supine" classes. In contrast, the accelerometer-based method employed a feedforward neural network trained on features extracted from segmented accelerometer data, such as signal sum, standard deviation, maximum, and spike count. This method yielded superior performance, reaching an accuracy exceeding 99.8% across most sleep positions. The "wake up" position was particularly easy to detect due to the absence of body movements such as heartbeat or respiration when the person is no longer in bed. The results demonstrate that while image-based models are effective, accelerometer-based classification offers higher precision and robustness, particularly in real-time and privacy-sensitive scenarios. Further comparisons of the system characteristics, data size, and training time are also carried out to offer crucial insights for selecting the appropriate technology in clinical, in-home, or embedded healthcare monitoring applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-18
DOI
https://doi.org/10.3390/s25123816
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Benchmarking Accelerometer and CNN-Based Vision Systems for Sleep Posture Classification in Healthcare Applications

Guido Matrella, Minh Long Hoang, Paolo Ciampolini, Dalila Giannetto et al.
2 citations
Sensors
Non-Invasive Vital Sign Monitoring
1.35
article

Benchmarking Accelerometer and CNN-Based Vision Systems for Sleep Posture Classification in Healthcare Applications

Guido Matrella, Minh Long Hoang, Paolo Ciampolini, Dalila Giannetto, Paolo Craparo
article en
2 citations

Abstract

Sleep position recognition plays a crucial role in diagnosing and managing various health conditions, such as sleep apnea, pressure ulcers, and musculoskeletal disorders. Accurate monitoring of body posture during sleep can provide valuable insights for clinicians and support the development of intelligent healthcare systems. This research presents a comparative analysis of sleep position recognition using two distinct approaches: image-based deep learning and accelerometer-based classification. There are five classes: prone, supine, right side, left side, and wake up. For the image-based method, the Visual Geometry Group 16 (VGG16) convolutional neural network was fine-tuned with data augmentation strategies including rotation, reflection, scaling, and translation to enhance model generalization. The image-based model achieved an overall accuracy of 93.49%, with perfect precision and recall for "right side" and "wakeup" positions, but slightly lower performance for "left side" and "supine" classes. In contrast, the accelerometer-based method employed a feedforward neural network trained on features extracted from segmented accelerometer data, such as signal sum, standard deviation, maximum, and spike count. This method yielded superior performance, reaching an accuracy exceeding 99.8% across most sleep positions. The "wake up" position was particularly easy to detect due to the absence of body movements such as heartbeat or respiration when the person is no longer in bed. The results demonstrate that while image-based models are effective, accelerometer-based classification offers higher precision and robustness, particularly in real-time and privacy-sensitive scenarios. Further comparisons of the system characteristics, data size, and training time are also carried out to offer crucial insights for selecting the appropriate technology in clinical, in-home, or embedded healthcare monitoring applications.

SensorsVol. 25(12)
University of Parma (IT)
Openalex Percentile: Top 19%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.