The Reliability and Validity of an Instrumented Device for Tracking the Shoulder Range of Motion

Rotator cuff tears are common in individuals over 40, and physical therapy is often prescribed post-surgery. However, access can be limited by cost, convenience, and insurance coverage. CuffLink is a telehealth rehabilitation system that integrates the Strengthening and Stabilization System mechanical exerciser with the interACTION mobile health platform. The system includes a triple-axis accelerometer (LSM6DSOX + LIS3MDL FeatherWing), a rotary encoder, a VL530X time-of-flight sensor, and two wearable BioMech Health IMUs to capture upper-limb motion. CuffLink is designed to facilitate controlled, home-based exercise while enabling clinicians to remotely monitor joint function. Concurrent validity and test-retest reliability were used to assess device accuracy and repeatability. The results showed moderate to good validity for shoulder rotation (ICC = 0.81), device rotation (ICC = 0.94), and linear tracking (from zero: ICC = 0.75 and RMSE = 2.41; from start: ICC = 0.88 and RMSE = 2.02) and good reliability (e.g., RMSEs as low as 1.66 cm), with greater consistency in linear tracking compared to angular measures. Shoulder rotation and abduction exhibited higher variability in both validity and reliability measures. Future improvements will focus on manufacturability, signal stability, and force sensing. CuffLink supports accessible, data-driven rehabilitation and holds promise for advancing digital health in orthopedic recovery.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-18
DOI
https://doi.org/10.3390/s25123818
Citations
2
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
4.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Reliability and Validity of an Instrumented Device for Tracking the Shoulder Range of Motion

Michael P. McClincy, Stephanie Tanadini‐Lang, Leila Motlagh Scholle, Jennifer Oakley et al.
2 citations
Sensors
Shoulder Injury and Treatment
4.01
article

The Reliability and Validity of an Instrumented Device for Tracking the Shoulder Range of Motion

Michael P. McClincy, Stephanie Tanadini‐Lang, Leila Motlagh Scholle, Jennifer Oakley, Ashley Disantis, Simran Kulkarni, Kevin M. Bell, Michelle Riffitts, Bambang Parmanto, Robert Roos, Adam Popchak, Connor Luck, Andi Saptono, Jim Grant, Dharma Parmanto, Made D. Yoga, Erica Tatko, Vayu Putraadinatha, Jennifer Lambiase
article en
2 citations

Abstract

Rotator cuff tears are common in individuals over 40, and physical therapy is often prescribed post-surgery. However, access can be limited by cost, convenience, and insurance coverage. CuffLink is a telehealth rehabilitation system that integrates the Strengthening and Stabilization System mechanical exerciser with the interACTION mobile health platform. The system includes a triple-axis accelerometer (LSM6DSOX + LIS3MDL FeatherWing), a rotary encoder, a VL530X time-of-flight sensor, and two wearable BioMech Health IMUs to capture upper-limb motion. CuffLink is designed to facilitate controlled, home-based exercise while enabling clinicians to remotely monitor joint function. Concurrent validity and test-retest reliability were used to assess device accuracy and repeatability. The results showed moderate to good validity for shoulder rotation (ICC = 0.81), device rotation (ICC = 0.94), and linear tracking (from zero: ICC = 0.75 and RMSE = 2.41; from start: ICC = 0.88 and RMSE = 2.02) and good reliability (e.g., RMSEs as low as 1.66 cm), with greater consistency in linear tracking compared to angular measures. Shoulder rotation and abduction exhibited higher variability in both validity and reliability measures. Future improvements will focus on manufacturability, signal stability, and force sensing. CuffLink supports accessible, data-driven rehabilitation and holds promise for advancing digital health in orthopedic recovery.

SensorsVol. 25(12)
Duquesne University (US), University of Pittsburgh (US), Samueli Institute (US)
U.S. Department of Health and Human Services, University of Pittsburgh, Small Business Technology Transfer, National Institutes of Health
Openalex Percentile: Top 7%
Shoulder Injury and Treatment
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.