The Impact of Cardiac Output Methods on the Classification of Pulmonary Hypertension

Cardiac output is essential to calculate pulmonary vascular resistance (PVR) and classify pulmonary hypertension (PH). Recent evidence has shown a lower agreement between thermodilution (COTD) and direct Fick (CODF) methods than historically estimated. The influence of the cardiac output measurement method on the classification of PH is poorly explored. We aimed to estimate the risk of diagnostic error when using COTD instead of CODF. We used a previously published mathematical model to consecutive patients diagnosed with PH at three centers in Switzerland. This model allows an individual estimation of the risk of diagnostic error when using COTD instead of CODF and is based on limits of agreement (LoA) between COTD and CODF of 2 L/min (average estimation) and 2.7 L/min (worst case scenario estimation). One thousand one hundred and forty-two patients with PH were evaluated. The mean risk of diagnostic error using the model with LoA of 2 L/min was 6.0% in the overall population (<i>n</i> = 1142). The mean risk of diagnostic error was 2.9% among the 712 patients with precapillary PH, 15.0% among the 113 patients with isolated postcapillary PH (IpcPH), 7.2% among the 247 patients with combined post- and pre-capillary PH, and 18.8% among the 70 patients with unclassified PH. The estimated diagnostic error when using COTD instead of CODF was generally low, particularly for patients with precapillary PH. Patients with PVR close to the diagnostic threshold of 2 WU (i.e., between 1 and 3 WU), mostly concerning patients with IpcPH and unclassified PH, exhibited a higher risk of diagnostic error.

Authors

Institutions

Publication Details

Journal
Pulmonary Circulation
Published
2025-04-01
DOI
https://doi.org/10.1002/pul2.70112
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Cardiac Output Methods on the Classification of Pulmonary Hypertension

Maurice Beghetti, Stéphane Noble, Hugues Turbé, Christian Lovis et al.
Pulmonary Circulation
Pulmonary Hypertension Research and Treatments
article

The Impact of Cardiac Output Methods on the Classification of Pulmonary Hypertension

Maurice Beghetti, Stéphane Noble, Hugues Turbé, Christian Lovis, Silvia Ulrich, Julian Müller, Roberto Desponds, Julian Klug, Mona Lichtblau, Frédéric Lador, Julie Wacker, Benoît Lechartier, Léon Genecand, Gaëtan Simian, Olivier Sitbon, David Montani, Jean‐Marc Fellrath
article en

Abstract

Cardiac output is essential to calculate pulmonary vascular resistance (PVR) and classify pulmonary hypertension (PH). Recent evidence has shown a lower agreement between thermodilution (COTD) and direct Fick (CODF) methods than historically estimated. The influence of the cardiac output measurement method on the classification of PH is poorly explored. We aimed to estimate the risk of diagnostic error when using COTD instead of CODF. We used a previously published mathematical model to consecutive patients diagnosed with PH at three centers in Switzerland. This model allows an individual estimation of the risk of diagnostic error when using COTD instead of CODF and is based on limits of agreement (LoA) between COTD and CODF of 2 L/min (average estimation) and 2.7 L/min (worst case scenario estimation). One thousand one hundred and forty-two patients with PH were evaluated. The mean risk of diagnostic error using the model with LoA of 2 L/min was 6.0% in the overall population (<i>n</i> = 1142). The mean risk of diagnostic error was 2.9% among the 712 patients with precapillary PH, 15.0% among the 113 patients with isolated postcapillary PH (IpcPH), 7.2% among the 247 patients with combined post- and pre-capillary PH, and 18.8% among the 70 patients with unclassified PH. The estimated diagnostic error when using COTD instead of CODF was generally low, particularly for patients with precapillary PH. Patients with PVR close to the diagnostic threshold of 2 WU (i.e., between 1 and 3 WU), mostly concerning patients with IpcPH and unclassified PH, exhibited a higher risk of diagnostic error.

Pulmonary CirculationVol. 15(2)
University of Geneva (CH), University of Zurich (CH), Université Paris-Saclay (FR), Assistance Publique – Hôpitaux de Paris (FR), University Hospital of Zurich (CH), Hospital Neuchâtel (CH), University Hospital of Geneva (CH), Hypertension pulmonaire : physiopathologie et innovation thérapeutique (FR), Bicêtre Hospital (FR), University of Lausanne (CH)
Openalex Percentile: Top 76%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.