Study on the Effects of Wind Direction on the Characteristics of Vortex-Induced Vibration for a Square Cylinder

Due to its complex mechanism of action, the wind-resistant design of square cross-section structures against vortex-induced vibration (VIV) still presents significant challenges. The angle of the wind direction is an important factor affecting the VIV characteristics of square cylinders. A series of stationary model pressure tests were performed and an elastic supporting model was used in the present study. The effects of the wind direction angle on parameters corresponding to fluid–structure interaction were analyzed with reference to the Strouhal number, range of “lock-in”, amplitude, and aerodynamic forces. The Strouhal number of the square cylinder was greatest at a 16° wind direction angle. When the wind direction angle was 10°, the wind speed range of vortex-induced vibration (VIV) of the square cylinder was the greatest, and the corresponding value was the smallest when the wind direction angle ranged from 20° to 45°. Within the vibration interval, the extreme value of the amplitude was smallest when the wind direction angle was 10°, and the extreme value of the amplitude was greatest when the wind direction angle was 30°. The vibration state had a minimal influence on the mean lift coefficient and a relatively large influence on the mean drag coefficient.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-06-19
DOI
https://doi.org/10.3390/buildings15122129
Primary Topic
Fluid Dynamics and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Effects of Wind Direction on the Characteristics of Vortex-Induced Vibration for a Square Cylinder

Jing Tang Xing, Wenyong Ma, Xiaobin Zhang, Fei Wang et al.
Buildings
Fluid Dynamics and Vibration Analysis
article

Study on the Effects of Wind Direction on the Characteristics of Vortex-Induced Vibration for a Square Cylinder

Jing Tang Xing, Wenyong Ma, Xiaobin Zhang, Fei Wang, Yurong Gu, Qiuling Zhao
article en

Abstract

Due to its complex mechanism of action, the wind-resistant design of square cross-section structures against vortex-induced vibration (VIV) still presents significant challenges. The angle of the wind direction is an important factor affecting the VIV characteristics of square cylinders. A series of stationary model pressure tests were performed and an elastic supporting model was used in the present study. The effects of the wind direction angle on parameters corresponding to fluid–structure interaction were analyzed with reference to the Strouhal number, range of “lock-in”, amplitude, and aerodynamic forces. The Strouhal number of the square cylinder was greatest at a 16° wind direction angle. When the wind direction angle was 10°, the wind speed range of vortex-induced vibration (VIV) of the square cylinder was the greatest, and the corresponding value was the smallest when the wind direction angle ranged from 20° to 45°. Within the vibration interval, the extreme value of the amplitude was smallest when the wind direction angle was 10°, and the extreme value of the amplitude was greatest when the wind direction angle was 30°. The vibration state had a minimal influence on the mean lift coefficient and a relatively large influence on the mean drag coefficient.

BuildingsVol. 15(12)
Shijiazhuang Tiedao University (CN)
Affordable and clean energy
Openalex Percentile: Top 85%
Fluid Dynamics and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.