In Vitro Accuracy of Two Different Electronic Apex Locators Under Various Conditions

Background: The purpose of this study was to analyze the accuracy of two apex locators using seven different canal irrigants. Methods: Forty multi-rooted extracted teeth were included in this study. The actual canal length (ACL) was determined using a #10 file until the tip was visualized (12× magnification) just within the apical foramen (AF). The teeth were placed in a conductive medium of alginate to test the ACL and electronic canal length (ECL) using both apex locators in various conditions. Seven irrigant solutions were used in the root canal: 0.9% saline, FileEZE EDTA 19%, Glyde EDTA 17%, Consepsis V Chlorhexidine 2% CHX, Chlorcid 3%, citric acid 20%, and EDTA 18%. Results: Within a range of ±0.5 mm from the ACL, Raypex showed an accuracy of 87.5% with 0.9% saline solution, 82.5% with Chlorcid 3%, and 75% with Consepsis V CHX 2% solution. The Ipex showed an accuracy of 82.5% with 0.9% saline solution, 80% with Chlorcid 3%, and 70% with Consepsis V CHX 2% solution. The differences among the canal irrigants were significant for both the Raypex (p = 0.021) and Ipex (p < 0.0001) devices. The mean values showed the greatest variations in ECL accuracy with the combination of Raypex and EDTA 18% (p = 0.042) and with the Ipex and Glyde EDTA 17% (p = 0.026). Conclusions: Canal irrigants have an impact on the accuracy of apex locators. The apex locators showed an accuracy of 80% and greater when 0.9% saline and Chlorcid 3% solutions were used.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-06-18
DOI
https://doi.org/10.3390/app15126892
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Accuracy of Two Different Electronic Apex Locators Under Various Conditions

Walter Dukić, Lucija Koturić Čabraja
Applied Sciences
Endodontics and Root Canal Treatments
article

In Vitro Accuracy of Two Different Electronic Apex Locators Under Various Conditions

Walter Dukić, Lucija Koturić Čabraja
article en

Abstract

Background: The purpose of this study was to analyze the accuracy of two apex locators using seven different canal irrigants. Methods: Forty multi-rooted extracted teeth were included in this study. The actual canal length (ACL) was determined using a #10 file until the tip was visualized (12× magnification) just within the apical foramen (AF). The teeth were placed in a conductive medium of alginate to test the ACL and electronic canal length (ECL) using both apex locators in various conditions. Seven irrigant solutions were used in the root canal: 0.9% saline, FileEZE EDTA 19%, Glyde EDTA 17%, Consepsis V Chlorhexidine 2% CHX, Chlorcid 3%, citric acid 20%, and EDTA 18%. Results: Within a range of ±0.5 mm from the ACL, Raypex showed an accuracy of 87.5% with 0.9% saline solution, 82.5% with Chlorcid 3%, and 75% with Consepsis V CHX 2% solution. The Ipex showed an accuracy of 82.5% with 0.9% saline solution, 80% with Chlorcid 3%, and 70% with Consepsis V CHX 2% solution. The differences among the canal irrigants were significant for both the Raypex (p = 0.021) and Ipex (p < 0.0001) devices. The mean values showed the greatest variations in ECL accuracy with the combination of Raypex and EDTA 18% (p = 0.042) and with the Ipex and Glyde EDTA 17% (p = 0.026). Conclusions: Canal irrigants have an impact on the accuracy of apex locators. The apex locators showed an accuracy of 80% and greater when 0.9% saline and Chlorcid 3% solutions were used.

Applied SciencesVol. 15(12)
University of Zagreb (HR), Zagreb School of Business (HR)
Clean water and sanitation
Openalex Percentile: Top 81%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.