Study on optimization operation strategy of metro station air conditioning system with variable water temperature

In order to further optimize the variable water temperature operation strategy of the air-conditioning system to improve the energy saving performance, under the premise of meeting the thermal comfort requirements of building rooms in a sub-way station in Zhengzhou City, the most unfavorable room corresponding to the final equipment of the air-conditioning system was taken as the research object to study the rule of temperature and humidity changes with the supply chillered water temperature in the room during the air-conditioning period. The influence of supply chillered water temperature on indoor comfort under different load rates is analyzed. On this basis, the optimal control strategy of the supply chillered water temperature in the whole cooling season is set according to the room load rate, and the energy saving analysis is carried out. Under the condition that the indoor environment meets the requirements of thermal comfort temperature and humidity, the optimal chillered water temperature under different load rates is calculated. The research results show that the energy saving rate of the chiller is 13.06%, which effectively reduces the energy consumption of the system.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2025-01-01
DOI
https://doi.org/10.2298/tsci2503909y
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on optimization operation strategy of metro station air conditioning system with variable water temperature

Chao Liu, He Dasi, Jie Lan, Guangjin Li et al.
1 citations
Thermal Science
Building Energy and Comfort Optimization
1.01
article

Study on optimization operation strategy of metro station air conditioning system with variable water temperature

Chao Liu, He Dasi, Jie Lan, Guangjin Li, Sanxian Xia, Wen Sheng Yu
article en
1 citations

Abstract

In order to further optimize the variable water temperature operation strategy of the air-conditioning system to improve the energy saving performance, under the premise of meeting the thermal comfort requirements of building rooms in a sub-way station in Zhengzhou City, the most unfavorable room corresponding to the final equipment of the air-conditioning system was taken as the research object to study the rule of temperature and humidity changes with the supply chillered water temperature in the room during the air-conditioning period. The influence of supply chillered water temperature on indoor comfort under different load rates is analyzed. On this basis, the optimal control strategy of the supply chillered water temperature in the whole cooling season is set according to the room load rate, and the energy saving analysis is carried out. Under the condition that the indoor environment meets the requirements of thermal comfort temperature and humidity, the optimal chillered water temperature under different load rates is calculated. The research results show that the energy saving rate of the chiller is 13.06%, which effectively reduces the energy consumption of the system.

Thermal ScienceVol. 29(3 Part A)
Zhongyuan University of Technology (CN), Zhengzhou Railway Vocational & Technical College (CN)
Affordable and clean energy
Openalex Percentile: Top 24%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.