Experimental study on quasi-two-stage compression heat pump air conditioning system for pure electric bus

In response to the challenge of achieving efficient low temperature heating performance in heat pump air conditioning systems for pure electric buses, a quasi-two-stage compression heat pump air conditioning system incorporating fully micro-channel technology is developed. A series of experimental studies were conducted to investigate the influence of different compressor speeds and fan frequencies on system performance, resulting in corresponding performance curves. In a low temperature environment of -10?C, the compressor exhaust temperature is maintained at 44.34?C. Concurrently, the system heat exchange capacity is enhanced by 11.3% to 47% compared to the non-supplemented air system. Moreover, at a compressor speed of 4000 rpm, the system COP was found to be 2.72. The implementation of variable frequency compressor speed and fan frequency in the pure electric bus heat pump system has resulted in enhanced system performance, leading to energy savings.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2025-01-01
DOI
https://doi.org/10.2298/tsci2503981z
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on quasi-two-stage compression heat pump air conditioning system for pure electric bus

Haijun Li, Shengyong Liu, Dong Zhao, Gang Chen et al.
1 links
Thermal Science
Refrigeration and Air Conditioning Technologies
article

Experimental study on quasi-two-stage compression heat pump air conditioning system for pure electric bus

Haijun Li, Shengyong Liu, Dong Zhao, Gang Chen, Liying Tian
article en

Abstract

In response to the challenge of achieving efficient low temperature heating performance in heat pump air conditioning systems for pure electric buses, a quasi-two-stage compression heat pump air conditioning system incorporating fully micro-channel technology is developed. A series of experimental studies were conducted to investigate the influence of different compressor speeds and fan frequencies on system performance, resulting in corresponding performance curves. In a low temperature environment of -10?C, the compressor exhaust temperature is maintained at 44.34?C. Concurrently, the system heat exchange capacity is enhanced by 11.3% to 47% compared to the non-supplemented air system. Moreover, at a compressor speed of 4000 rpm, the system COP was found to be 2.72. The implementation of variable frequency compressor speed and fan frequency in the pure electric bus heat pump system has resulted in enhanced system performance, leading to energy savings.

Thermal ScienceVol. 29(3 Part A)
Zhongyuan University of Technology (CN), Henan Agricultural University (CN)
Affordable and clean energy
Openalex Percentile: Top 86%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.