Impact of the R407C and R134yf refrigerant charge on the performance of a new pure electric vehicle heat pump air conditioning system

The objective of this study was to investigate the impact of varying refrigerant charge levels of R407c and R134yf on the refrigeration performance of a vehicle heat pump air conditioning system. The study was conducted under high temperature conditions (45?C) to assess the influence of different refrigerant systems on refrigeration performance parameters. The results demonstrated that the optimal refrigerant charge level can be determined by analyzing the change in refrigeration performance parameters with varying charge levels. The results indicated that an increase in the refrigerant charge of R407c from 2.3 kg to 2.6 kg resulted in a maximum cooling capacity and COP of the system reaching 4.935 kW and 2.1, respectively. The optimal charging capacity of the system was determined to be 2.5 kg. Similarly, an increase in the refrigerant charging capacity of R134yf from 2.3 kg to 3.5 kg resulted in a maximum cooling capacity and COP of the system reaching 5.08 kW and 2.71, respectively. The optimal charging capacity of the system was determined to be 2.9 kg. The COP of the R134yf system is 0.61 higher than that of the R407c system. Furthermore, the energy saving of the R134yf system is more pronounced under extreme conditions.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2025-01-01
DOI
https://doi.org/10.2298/tsci2503943s
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of the R407C and R134yf refrigerant charge on the performance of a new pure electric vehicle heat pump air conditioning system

Yong-Min Yu, Yayu Dai, Zhiyong Su, Gang Chen et al.
1 citations
Thermal Science
Refrigeration and Air Conditioning Technologies
0.71
article

Impact of the R407C and R134yf refrigerant charge on the performance of a new pure electric vehicle heat pump air conditioning system

Yong-Min Yu, Yayu Dai, Zhiyong Su, Gang Chen, Haijun Li, Xinyu Tang, Hui Zeng, Minghan Xu
article en
1 citations

Abstract

The objective of this study was to investigate the impact of varying refrigerant charge levels of R407c and R134yf on the refrigeration performance of a vehicle heat pump air conditioning system. The study was conducted under high temperature conditions (45?C) to assess the influence of different refrigerant systems on refrigeration performance parameters. The results demonstrated that the optimal refrigerant charge level can be determined by analyzing the change in refrigeration performance parameters with varying charge levels. The results indicated that an increase in the refrigerant charge of R407c from 2.3 kg to 2.6 kg resulted in a maximum cooling capacity and COP of the system reaching 4.935 kW and 2.1, respectively. The optimal charging capacity of the system was determined to be 2.5 kg. Similarly, an increase in the refrigerant charging capacity of R134yf from 2.3 kg to 3.5 kg resulted in a maximum cooling capacity and COP of the system reaching 5.08 kW and 2.71, respectively. The optimal charging capacity of the system was determined to be 2.9 kg. The COP of the R134yf system is 0.61 higher than that of the R407c system. Furthermore, the energy saving of the R134yf system is more pronounced under extreme conditions.

Thermal ScienceVol. 29(3 Part A)
Zhongyuan University of Technology (CN), Shanghai Jinyuan Senior High School (CN)
Affordable and clean energy
Openalex Percentile: Top 31%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of the R407C and R134yf refrigerant charge on the performance of a new pure electric vehicle heat pump air conditioning system — Yong-Min Yu, Yayu Dai, et al. · Thermal Science (2025) | TGRS Research Map | TGRS