Synthesis and In Vitro Evaluation of a Scandium-44 Radiolabeled Nanobody as a PD-L1 PET Imaging Probe

<b>Background/Objective</b>: Noninvasive PET imaging-based assessment of PD-L1 expression is of high clinical value for better patient selection and treatment response rates to PD-L1 immunotherapies. Due to their shorter biological half-life and faster clearance from the blood pool, radiolabeled antibody fragments are an attractive alternative for imaging than their full-length IgG counterpart. This work investigated the radiosynthesis and in vitro cell uptake of anti-PD-L1-B11-nanobody radiolabeled with <sup>44</sup>Sc (t<sub>1/2</sub> = 4.04 h) as an alternative to anti-PD-L1-B11-IgG, better suited for longer half-life radioisotopes such as <sup>89</sup>Zr (t<sub>1/2</sub> = 78.41 h). <b>Methods</b>: The proteins were conjugated with p-SCN-Bn-DTPA and radiolabeled at room temperature with <sup>44</sup>Sc, achieving a radiochemical yield of a RCY of 94.8 ± 3.1% (<i>n</i> = 3) for [<sup>44</sup>Sc]Sc-B11-IgG and 73.6 ± 12.1% (<i>n</i> = 3) for [<sup>44</sup>Sc]Sc-B11-nanobody, before purification. <b>Results</b>: Significantly higher uptake in the PD-L1<sub>+</sub> cells than PD-L1<sub>KO</sub> cells was observed for both probes. However, high non-specific uptake, particularly of the radiolabeled B11-nanobody, was also observed which may negatively impact its potential as a molecular imaging probe. <b>Conclusions</b>: Due to the high non-specific uptake in vitro, the <sup>44</sup>Sc radiolabeled nanobody was not progressed to further in vivo evaluation. These results should, however, not discourage future evaluations of other nanobody based probes radiolabeled with <sup>44</sup>Sc, due to their well-matched biological and physical half-life.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2025-06-19
DOI
https://doi.org/10.3390/pharmaceutics17060796
Citations
2
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis and In Vitro Evaluation of a Scandium-44 Radiolabeled Nanobody as a PD-L1 PET Imaging Probe

Sean S. Park, Aditya Bansal, Haidong Dong, Viktoria Krol et al.
2 citations
Pharmaceutics
Radiopharmaceutical Chemistry and Applications
2.72
article

Synthesis and In Vitro Evaluation of a Scandium-44 Radiolabeled Nanobody as a PD-L1 PET Imaging Probe

Sean S. Park, Aditya Bansal, Haidong Dong, Viktoria Krol, Jason R. Ellinghuysen, Daniel J. Vail, Mukesh K. Pandey, Fabrice Lucien, Manasa Kethamreddy
article en
2 citations

Abstract

<b>Background/Objective</b>: Noninvasive PET imaging-based assessment of PD-L1 expression is of high clinical value for better patient selection and treatment response rates to PD-L1 immunotherapies. Due to their shorter biological half-life and faster clearance from the blood pool, radiolabeled antibody fragments are an attractive alternative for imaging than their full-length IgG counterpart. This work investigated the radiosynthesis and in vitro cell uptake of anti-PD-L1-B11-nanobody radiolabeled with <sup>44</sup>Sc (t<sub>1/2</sub> = 4.04 h) as an alternative to anti-PD-L1-B11-IgG, better suited for longer half-life radioisotopes such as <sup>89</sup>Zr (t<sub>1/2</sub> = 78.41 h). <b>Methods</b>: The proteins were conjugated with p-SCN-Bn-DTPA and radiolabeled at room temperature with <sup>44</sup>Sc, achieving a radiochemical yield of a RCY of 94.8 ± 3.1% (<i>n</i> = 3) for [<sup>44</sup>Sc]Sc-B11-IgG and 73.6 ± 12.1% (<i>n</i> = 3) for [<sup>44</sup>Sc]Sc-B11-nanobody, before purification. <b>Results</b>: Significantly higher uptake in the PD-L1<sub>+</sub> cells than PD-L1<sub>KO</sub> cells was observed for both probes. However, high non-specific uptake, particularly of the radiolabeled B11-nanobody, was also observed which may negatively impact its potential as a molecular imaging probe. <b>Conclusions</b>: Due to the high non-specific uptake in vitro, the <sup>44</sup>Sc radiolabeled nanobody was not progressed to further in vivo evaluation. These results should, however, not discourage future evaluations of other nanobody based probes radiolabeled with <sup>44</sup>Sc, due to their well-matched biological and physical half-life.

PharmaceuticsVol. 17(6)
Mayo Clinic (US), WinnMed (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US)
Openalex Percentile: Top 10%
Radiopharmaceutical Chemistry and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.