Experimental and Theoretical Evaluation of Buoyancy Reduction in Saturated Clay Soils

The rational calculation of groundwater buoyancy directly impacts the safety of underground engineering. However, there is still no consensus on whether the reduction of groundwater buoyancy should be considered, and a theoretical explanation and quantification of buoyancy reduction in clayey soils is lacking. Based on laboratory engineering model tests, this study observed and analyzed the phenomenon of buoyancy reduction in saturated clayey soils. The contact area ratio of gravity water, calculated from geotechnical test data, was compared with the reduction slope. The experimental results indicated that the reduction slope of the fitted line between the static water head in the silty clay layer and the buoyancy water head was 0.8692. And theoretical analysis showed that the distribution of interparticle pore water pressure tends to attenuate from the pore center to the soil particle surface, suggesting a reduction in buoyancy head compared to the groundwater level. The reduction slope is theoretically equal to the contact area ratio of gravity water. Additionally, since limitations in current techniques for generalizing the soil–water constitutive models affect the reduction slope, this study proposes a method for determining the buoyancy reduction slope in saturated clayey soil based on the theory that interparticle pore water pressure distribution attenuates from the pore center to the soil particle surface. This method could potentially change the existing conceptual framework for buoyancy design in underground structures.

Authors

Institutions

Publication Details

Journal
Water
Published
2025-06-19
DOI
https://doi.org/10.3390/w17121832
Citations
1
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Theoretical Evaluation of Buoyancy Reduction in Saturated Clay Soils

Xiaomin Zhou, Hongyan Liu, Yubo Wang, Ting Gao et al.
1 citations
Water
Geotechnical Engineering and Underground Structures
0.95
article

Experimental and Theoretical Evaluation of Buoyancy Reduction in Saturated Clay Soils

Xiaomin Zhou, Hongyan Liu, Yubo Wang, Ting Gao, Yongliang Xu
article en
1 citations

Abstract

The rational calculation of groundwater buoyancy directly impacts the safety of underground engineering. However, there is still no consensus on whether the reduction of groundwater buoyancy should be considered, and a theoretical explanation and quantification of buoyancy reduction in clayey soils is lacking. Based on laboratory engineering model tests, this study observed and analyzed the phenomenon of buoyancy reduction in saturated clayey soils. The contact area ratio of gravity water, calculated from geotechnical test data, was compared with the reduction slope. The experimental results indicated that the reduction slope of the fitted line between the static water head in the silty clay layer and the buoyancy water head was 0.8692. And theoretical analysis showed that the distribution of interparticle pore water pressure tends to attenuate from the pore center to the soil particle surface, suggesting a reduction in buoyancy head compared to the groundwater level. The reduction slope is theoretically equal to the contact area ratio of gravity water. Additionally, since limitations in current techniques for generalizing the soil–water constitutive models affect the reduction slope, this study proposes a method for determining the buoyancy reduction slope in saturated clayey soil based on the theory that interparticle pore water pressure distribution attenuates from the pore center to the soil particle surface. This method could potentially change the existing conceptual framework for buoyancy design in underground structures.

WaterVol. 17(12)
Shanghai Tunnel Engineering Rail Transit Design & Research Institute (CN), Beijing Urban Construction Design & Development Group (China) (CN), University of Science and Technology Beijing (CN)
Openalex Percentile: Top 25%
Geotechnical Engineering and Underground Structures
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental and Theoretical Evaluation of Buoyancy Reduction in Saturated Clay Soils — Xiaomin Zhou, Hongyan Liu, et al. · Water (2025) | TGRS Research Map | TGRS