Experimental Study on Glass Deformation Calculation Using the Holographic Interferometry Double-Exposure Method

This study systematically compares the metrological characteristics of single- exposure, double-exposure, and continuous-exposure holographic interferometry for micro-deformation detection. Results demonstrate that the double-exposure method achieves optimal balance across critical performance metrics through its ideal cosine fringe field modulation. This approach (1) eliminates object wave amplitude interference via dual-exposure superposition, establishing submicron linear mapping between fringe displacement and deformation amplitude; (2) introduces a fringe gradient-based direction detection algorithm resolving deformation vector ambiguity; and (3) implements an error-compensated fusion framework integrating theoretical modeling, MATLAB 2015b simulations, and experimental validation. Experiments on drilled glass samples confirm their superior performance in terms of near-ideal fringe contrast (1.0) and noise suppression (0.06). The technique significantly improves real-time capability and anti-interference robustness in micro-deformation monitoring, providing a validated solution for MEMS and material mechanics characterization.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-06-19
DOI
https://doi.org/10.3390/app15126938
Citations
1
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Glass Deformation Calculation Using the Holographic Interferometry Double-Exposure Method

Muqun Zhang, Yang Zhang, Yucheng Li, Song Gao et al.
1 citations
Applied Sciences
Optical measurement and interference techniques
1.28
article

Experimental Study on Glass Deformation Calculation Using the Holographic Interferometry Double-Exposure Method

Muqun Zhang, Yang Zhang, Yucheng Li, Song Gao, Deyu Jia
article en
1 citations

Abstract

This study systematically compares the metrological characteristics of single- exposure, double-exposure, and continuous-exposure holographic interferometry for micro-deformation detection. Results demonstrate that the double-exposure method achieves optimal balance across critical performance metrics through its ideal cosine fringe field modulation. This approach (1) eliminates object wave amplitude interference via dual-exposure superposition, establishing submicron linear mapping between fringe displacement and deformation amplitude; (2) introduces a fringe gradient-based direction detection algorithm resolving deformation vector ambiguity; and (3) implements an error-compensated fusion framework integrating theoretical modeling, MATLAB 2015b simulations, and experimental validation. Experiments on drilled glass samples confirm their superior performance in terms of near-ideal fringe contrast (1.0) and noise suppression (0.06). The technique significantly improves real-time capability and anti-interference robustness in micro-deformation monitoring, providing a validated solution for MEMS and material mechanics characterization.

Applied SciencesVol. 15(12)
Air Force Engineering University (CN)
Openalex Percentile: Top 19%
Optical measurement and interference techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.