Efficiency of Diagnosing Electrotechnical Components of Hydraulic Equipment

Diagnostics of electrical components of hydrotechnical equipment used in agricultural production within the planned maintenance intervals with continuous analysis of residual resource is useful for reducing equipment operation costs. The use of inexpensive universal diagnostic equipment in conjunction with primary analysis of the state of units makes it possible to detect 60 to 80% of prefailure states. To ensure efficient application of the complex approach to primary diagnostics of electrical components of hydraulic equipment used in agricultural production, the authors considered the most common electric motors of pumping units, electrohydraulic distributors, and switching equipment. Complex diagnostics included the use of a thermal imager, vibration signal processing systems, and current signal control systems. The vibrograms of equipment control points were analyzed, and the state of bearing units as well as the cavitation characteristics of pumps were assessed by methods of acoustic and vibration diagnostics; hydraulic equipment leaks were searched, and power cables breakdown zones were detected in accordance with methodical instructions for determining the breakdowns of power cables with a voltage of up to 10 kV (RD 34.20.516-90). The article shows the possibilities of applying the diagnostics methodology based on surface thermograms to determine typical defects. Particularly discussed are the parameters of current signals from the electromagnet coils observed in case of distribution equipment malfunction. The authors give comparative estimation of diagnostics methods with calculated efficiency determination. It is established that the method of combined diagnostics using the analysis of external thermal fields can halve the time of preliminary diagnostics of faults with a stable forecast of the failure time 2–3 months before the critical state. This reduces the expenditures for detection of unit failures and simplifies the planning of maintenance procedures.

Authors

Institutions

Publication Details

Journal
Technical Physics
Published
2025-03-01
DOI
https://doi.org/10.1134/s1063784225700203
Citations
1
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficiency of Diagnosing Electrotechnical Components of Hydraulic Equipment

Vladimir Storchevoy, Elena Akhmedyanova, S.N. Rednikov, T. I. Matveeva
1 citations
Technical Physics
Engineering Diagnostics and Reliability
0.86
article

Efficiency of Diagnosing Electrotechnical Components of Hydraulic Equipment

Vladimir Storchevoy, Elena Akhmedyanova, S.N. Rednikov, T. I. Matveeva
article en
1 citations

Abstract

Diagnostics of electrical components of hydrotechnical equipment used in agricultural production within the planned maintenance intervals with continuous analysis of residual resource is useful for reducing equipment operation costs. The use of inexpensive universal diagnostic equipment in conjunction with primary analysis of the state of units makes it possible to detect 60 to 80% of prefailure states. To ensure efficient application of the complex approach to primary diagnostics of electrical components of hydraulic equipment used in agricultural production, the authors considered the most common electric motors of pumping units, electrohydraulic distributors, and switching equipment. Complex diagnostics included the use of a thermal imager, vibration signal processing systems, and current signal control systems. The vibrograms of equipment control points were analyzed, and the state of bearing units as well as the cavitation characteristics of pumps were assessed by methods of acoustic and vibration diagnostics; hydraulic equipment leaks were searched, and power cables breakdown zones were detected in accordance with methodical instructions for determining the breakdowns of power cables with a voltage of up to 10 kV (RD 34.20.516-90). The article shows the possibilities of applying the diagnostics methodology based on surface thermograms to determine typical defects. Particularly discussed are the parameters of current signals from the electromagnet coils observed in case of distribution equipment malfunction. The authors give comparative estimation of diagnostics methods with calculated efficiency determination. It is established that the method of combined diagnostics using the analysis of external thermal fields can halve the time of preliminary diagnostics of faults with a stable forecast of the failure time 2–3 months before the critical state. This reduces the expenditures for detection of unit failures and simplifies the planning of maintenance procedures.

Technical PhysicsVol. 70(3)
Moscow State Agroengineering University named after V.P. Goryachkin (RU)
Affordable and clean energy
Openalex Percentile: Top 29%
Engineering Diagnostics and Reliability
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.