mmWave Imaging Enabled Multi-Site Respiratory Monitoring

This study presents an advanced high-resolution mmWave radar imaging system for multi-site respiratory monitoring, utilizing MIMO (Multi-Input Multi-Output) radar technology to enhance spatial resolution in monitoring respiration. The imaging system incorporates multi-element uniform linear transmit and receive antenna arrays, producing detailed 3-D radar backscatter grids to capture subtle respiratory motions across multiple body sites. Through MIMO beamforming and spatial coherence mapping, the system identifies respiration intensity and motion patterns at the chest and abdomen, validating the radar's performance against standard BIOPAC respiratory data. Results indicate significant potential for non-contact, multi-site respiratory assessment, enhancing traditional radar applications with improved resolution and sensitivity.

Authors

Institutions

Publication Details

Published
2025-05-03
DOI
https://doi.org/10.1109/radar52380.2025.11031765
Primary Topic
Indoor and Outdoor Localization Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

mmWave Imaging Enabled Multi-Site Respiratory Monitoring

Jesus Antonio Sanchez-Perez, Daniel W. Bliss, Drake Silbernagel, Adarsh A. Venkataramani et al.
Indoor and Outdoor Localization Technologies
article

mmWave Imaging Enabled Multi-Site Respiratory Monitoring

Jesus Antonio Sanchez-Perez, Daniel W. Bliss, Drake Silbernagel, Adarsh A. Venkataramani, Yu Rong
article en

Abstract

This study presents an advanced high-resolution mmWave radar imaging system for multi-site respiratory monitoring, utilizing MIMO (Multi-Input Multi-Output) radar technology to enhance spatial resolution in monitoring respiration. The imaging system incorporates multi-element uniform linear transmit and receive antenna arrays, producing detailed 3-D radar backscatter grids to capture subtle respiratory motions across multiple body sites. Through MIMO beamforming and spatial coherence mapping, the system identifies respiration intensity and motion patterns at the chest and abdomen, validating the radar's performance against standard BIOPAC respiratory data. Results indicate significant potential for non-contact, multi-site respiratory assessment, enhancing traditional radar applications with improved resolution and sensitivity.

University of New Mexico (US), Arizona State University (US), University of Puerto Rico-Mayaguez (PR)
Openalex Percentile: Top 88%
Indoor and Outdoor Localization Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

mmWave Imaging Enabled Multi-Site Respiratory Monitoring — Jesus Antonio Sanchez-Perez, Daniel W. Bliss, et al. · (2025) | TGRS Research Map | TGRS