Design and Fabrication of Flexible Thin-Wire Multispot Thermocouples Using Hot-Wire Coating

Temperature measurement is still one of the most important applications for sensor devices. Besides resistive thermal sensors, semiconductor devices, and infrared thermal sensors, thermoelectric devices (or thermocouples) are widely used. This work presents a sensor concept and an associated fabrication method for flexible thermoelectric sensors based on a single metal wire substrate with a diameter of only 80 μm covered by one or multiple coating layers of isolating and conductive materials. These devices are fabricated using hot-wire coating technology, where an electric current heats the substrate via Joule heating, causing applied inks to cure nearly instantly. Due to the small diameter of the used wires, the sensors are not only highly flexible but also feature ultra-low response times. The samples are fabricated by coating a commercially available 80 μm thick copper wire with multiple layers of poly(3,4-ethylene-dioxythiophene:styrene sulfonate) (PEDOT:PSS) and silver ink separated by layers of polyamide-imide (PAI) for insulation. Intentional gaps (“holes”) in the insulation allow for the electrical connection of different layers, creating the hot junction of a thermocouple. This design allows for any number of thermocouples to be integrated into a single wire, provided that enough layers of conductive material are provided. The fabricated samples feature thermocouples utilizing copper-PEDOT:PSS as well as silver-PEDOT:PSS junctions, showing different sensitivities to temperature. The thermocouples were characterized to investigate possible differences between material combinations and solvent mixtures and showed a large but expected deviation when comparing two different PEDOT:PSS solutions. The sensitivity was measured to be around 6.3 μV/K and 13 μV/K respectively, for both copper-PEDOT:PSS-thermocouple variants and 9.4 μV/K for the silver-PEDOT:PSS-thermocouples.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2025-06-19
DOI
https://doi.org/10.1109/lsens.2025.3581292
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Fabrication of Flexible Thin-Wire Multispot Thermocouples Using Hot-Wire Coating

Sebastian Lang, Wolfgang Hilber, Bernhard Jakoby, Tina Mitteramskogler
IEEE Sensors Letters
Advanced Sensor Technologies Research
article

Design and Fabrication of Flexible Thin-Wire Multispot Thermocouples Using Hot-Wire Coating

Sebastian Lang, Wolfgang Hilber, Bernhard Jakoby, Tina Mitteramskogler
article en

Abstract

Temperature measurement is still one of the most important applications for sensor devices. Besides resistive thermal sensors, semiconductor devices, and infrared thermal sensors, thermoelectric devices (or thermocouples) are widely used. This work presents a sensor concept and an associated fabrication method for flexible thermoelectric sensors based on a single metal wire substrate with a diameter of only 80 μm covered by one or multiple coating layers of isolating and conductive materials. These devices are fabricated using hot-wire coating technology, where an electric current heats the substrate via Joule heating, causing applied inks to cure nearly instantly. Due to the small diameter of the used wires, the sensors are not only highly flexible but also feature ultra-low response times. The samples are fabricated by coating a commercially available 80 μm thick copper wire with multiple layers of poly(3,4-ethylene-dioxythiophene:styrene sulfonate) (PEDOT:PSS) and silver ink separated by layers of polyamide-imide (PAI) for insulation. Intentional gaps (“holes”) in the insulation allow for the electrical connection of different layers, creating the hot junction of a thermocouple. This design allows for any number of thermocouples to be integrated into a single wire, provided that enough layers of conductive material are provided. The fabricated samples feature thermocouples utilizing copper-PEDOT:PSS as well as silver-PEDOT:PSS junctions, showing different sensitivities to temperature. The thermocouples were characterized to investigate possible differences between material combinations and solvent mixtures and showed a large but expected deviation when comparing two different PEDOT:PSS solutions. The sensitivity was measured to be around 6.3 μV/K and 13 μV/K respectively, for both copper-PEDOT:PSS-thermocouple variants and 9.4 μV/K for the silver-PEDOT:PSS-thermocouples.

IEEE Sensors LettersVol. 9(7)
Johannes Kepler University of Linz (AT)
Openalex Percentile: Top 87%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.