Fluoroscopic Shape and Pose Tracking of Catheters With Custom Radiopaque Markers

Safe navigation of steerable and robotic catheters in the cerebral vasculature requires awareness of the catheter's shape and pose. Currently, a significant perception burden is placed on interventionalists to mentally reconstruct and predict catheter motions from biplane fluoroscopy images. Efforts to track these catheters are limited to planar segmentation or bulky sensing instrumentation, which are incompatible with microcatheters used in neurointervention. In this work, a catheter is equipped with custom radiopaque markers arranged to enable simultaneous shape and pose estimation under biplane fluoroscopy. A design measure is proposed to guide the arrangement of these markers to minimize sensitivity to marker tracking uncertainty. This approach was deployed for microcatheters (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\leq \phi 2\rm {mm}$</tex-math></inline-formula>) navigating phantom vasculature with shape tracking errors <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$&lt; $</tex-math></inline-formula>1mm and catheter roll errors <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$&lt; 40^{\circ }$</tex-math></inline-formula>. This work can enable steerable catheters to autonomously navigate under biplane imaging.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2025-06-19
DOI
https://doi.org/10.1109/lra.2025.3581043
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fluoroscopic Shape and Pose Tracking of Catheters With Custom Radiopaque Markers

Jared Lawson, Nabil Simaan, Rohan Chitale
1 links
IEEE Robotics and Automation Letters
Central Venous Catheters and Hemodialysis
article

Fluoroscopic Shape and Pose Tracking of Catheters With Custom Radiopaque Markers

Jared Lawson, Nabil Simaan, Rohan Chitale
article en

Abstract

Safe navigation of steerable and robotic catheters in the cerebral vasculature requires awareness of the catheter's shape and pose. Currently, a significant perception burden is placed on interventionalists to mentally reconstruct and predict catheter motions from biplane fluoroscopy images. Efforts to track these catheters are limited to planar segmentation or bulky sensing instrumentation, which are incompatible with microcatheters used in neurointervention. In this work, a catheter is equipped with custom radiopaque markers arranged to enable simultaneous shape and pose estimation under biplane fluoroscopy. A design measure is proposed to guide the arrangement of these markers to minimize sensitivity to marker tracking uncertainty. This approach was deployed for microcatheters (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\leq \phi 2\rm {mm}$</tex-math></inline-formula>) navigating phantom vasculature with shape tracking errors <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$&lt; $</tex-math></inline-formula>1mm and catheter roll errors <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$&lt; 40^{\circ }$</tex-math></inline-formula>. This work can enable steerable catheters to autonomously navigate under biplane imaging.

IEEE Robotics and Automation LettersVol. 10(8)
Vanderbilt University (US), Neurological Surgery (US), Vanderbilt University Medical Center (US)
Openalex Percentile: Top 76%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fluoroscopic Shape and Pose Tracking of Catheters With Custom Radiopaque Markers — Jared Lawson, Nabil Simaan, et al. · IEEE Robotics and Automation Letters (2025) | TGRS Research Map | TGRS