DIFFERENTIATING TARGET PERFOR-MANCE LEVEL FOR SEISMIC DESIGN BASED ON USE OF BUILDING
This study conducted an analysis to differentiate target performance levels for seismic design based on the intended use of buildings. The seismic hazard assessment of spectral accelerations, published by the Headquarters for Earthquake Research Promotion, was utilized to calibrate the current practices of seismic design in Japan, including the importance factors used for governmental facilities.
Authors
- Tatsuya Itoi (ORCID: https://orcid.org/0000-0003-3522-7101)
- Akihiro KUSAKA
- Yasuhiro Mori
Institutions
- The University of Tokyo (JP)
Publication Details
- Journal
- AIJ Journal of Technology and Design
- Published
- 2025-06-19
- DOI
- https://doi.org/10.3130/aijt.31.658
- Primary Topic
- Seismic Performance and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00