Quantitative evaluation method for severity of transformer discharge faults based on weighted carbon–hydrogen ratio of characteristic gases

Abstract Dissolved gas analysis (DGA) has been widely used for the condition diagnosis of oil-filled equipment. However, it mainly focuses on analyzing gas generation characteristics and diagnosing fault types, making it challenging to quantitatively assess the severity of faults. In this study, a discharge test platform was established to simulate discharge faults under different intensities. The content and relative percentage of dissolved gases in oil at varying discharge intensities were compared and studied. Experimental results showed that as the discharge intensity increased, the proportion of hydrocarbon gases followed the order: CH 4 → C 2 H 6 → C 2 H 4 → C 2 H 2 , with the carbon-to-hydrogen ratio of the corresponding characteristic gases also increasing. Based on this, a quantitative evaluation method for the severity of transformer discharge faults was proposed, using the weighted carbon-hydrogen ratio (R CH ) of characteristic gases. Case studies demonstrate that, compared with traditional DGA methods, this new method can quantitatively assess fault severity and overcome the limitations of the three-ratio method, such as discontinuity and missing codes, offering higher accuracy and sensitivity.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-06-19
DOI
https://doi.org/10.1088/1361-6501/ade616
Citations
2
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative evaluation method for severity of transformer discharge faults based on weighted carbon–hydrogen ratio of characteristic gases

Lin Du, Ningning Cai, P. Wei
2 citations
Measurement Science and Technology
Power Transformer Diagnostics and Insulation
1.46
article

Quantitative evaluation method for severity of transformer discharge faults based on weighted carbon–hydrogen ratio of characteristic gases

Lin Du, Ningning Cai, P. Wei
article en
2 citations

Abstract

Abstract Dissolved gas analysis (DGA) has been widely used for the condition diagnosis of oil-filled equipment. However, it mainly focuses on analyzing gas generation characteristics and diagnosing fault types, making it challenging to quantitatively assess the severity of faults. In this study, a discharge test platform was established to simulate discharge faults under different intensities. The content and relative percentage of dissolved gases in oil at varying discharge intensities were compared and studied. Experimental results showed that as the discharge intensity increased, the proportion of hydrocarbon gases followed the order: CH 4 → C 2 H 6 → C 2 H 4 → C 2 H 2 , with the carbon-to-hydrogen ratio of the corresponding characteristic gases also increasing. Based on this, a quantitative evaluation method for the severity of transformer discharge faults was proposed, using the weighted carbon-hydrogen ratio (R CH ) of characteristic gases. Case studies demonstrate that, compared with traditional DGA methods, this new method can quantitatively assess fault severity and overcome the limitations of the three-ratio method, such as discontinuity and missing codes, offering higher accuracy and sensitivity.

Measurement Science and TechnologyVol. 36(7)
Chongqing University (CN), State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 17%
Power Transformer Diagnostics and Insulation
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.