Hemodynamics and contact simulation investigation of coronary artery stents after interventional surgery

<i>Objective.</i>Interventional therapy represents a primary treatment modality for moderate to severe coronary atherosclerosis. However, potential complications following stent implantation can pose significant risks to patients. This study aims to explore the relationship between aberrant hemodynamic patterns and the incidence of post-stent implantation complications.<i>Approach.</i>By creating models of three distinct types of coronary artery stents and utilizing clinical fractional flow reserve data, this research employs fluid-structure interaction analyses to simulate the hemodynamic alterations and vascular wall responses post-stent implantation.<i>Main results.</i>It is indicated that implantation of stents can induce complex hemodynamic modifications in the vicinity of the stent, particularly at the juncture where the stent contacts the vascular wall. While the hemodynamic profiles of the three stent types exhibit general consistency, distinctions in local hemodynamics arise from the varied pore densities inherent to each stent design. Notably, the B-type stent, characterized by their moderate pore density, demonstrates comparatively stable hemodynamics relative to the other stent types. Additionally, stent implantation impacts areas of the vascular wall not covered by the stent, with notable hemodynamic changes also manifesting in these regions.<i>Significance.</i>The implantation of stents has a significant impact on the hemodynamics inside the blood vessels. Specifically, abnormal hemodynamic changes near the stents can inflict damage to the blood vessel wall, thus accelerating the occurrence of complications. Moreover, the hemodynamic changes elicited by different stents vary significantly, and it has been observed that stents with moderate grid spacing exhibit superior performance in mitigating adverse hemodynamic effects.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2025-06-19
DOI
https://doi.org/10.1088/1361-6579/ade652
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hemodynamics and contact simulation investigation of coronary artery stents after interventional surgery

Shikun Zhang, Hao Wei, Mimi Xu, Yinghong Zhao et al.
Physiological Measurement
Coronary Interventions and Diagnostics
article

Hemodynamics and contact simulation investigation of coronary artery stents after interventional surgery

Shikun Zhang, Hao Wei, Mimi Xu, Yinghong Zhao, Hui Tang, Ning Dang
article en

Abstract

<i>Objective.</i>Interventional therapy represents a primary treatment modality for moderate to severe coronary atherosclerosis. However, potential complications following stent implantation can pose significant risks to patients. This study aims to explore the relationship between aberrant hemodynamic patterns and the incidence of post-stent implantation complications.<i>Approach.</i>By creating models of three distinct types of coronary artery stents and utilizing clinical fractional flow reserve data, this research employs fluid-structure interaction analyses to simulate the hemodynamic alterations and vascular wall responses post-stent implantation.<i>Main results.</i>It is indicated that implantation of stents can induce complex hemodynamic modifications in the vicinity of the stent, particularly at the juncture where the stent contacts the vascular wall. While the hemodynamic profiles of the three stent types exhibit general consistency, distinctions in local hemodynamics arise from the varied pore densities inherent to each stent design. Notably, the B-type stent, characterized by their moderate pore density, demonstrates comparatively stable hemodynamics relative to the other stent types. Additionally, stent implantation impacts areas of the vascular wall not covered by the stent, with notable hemodynamic changes also manifesting in these regions.<i>Significance.</i>The implantation of stents has a significant impact on the hemodynamics inside the blood vessels. Specifically, abnormal hemodynamic changes near the stents can inflict damage to the blood vessel wall, thus accelerating the occurrence of complications. Moreover, the hemodynamic changes elicited by different stents vary significantly, and it has been observed that stents with moderate grid spacing exhibit superior performance in mitigating adverse hemodynamic effects.

Physiological MeasurementVol. 46(6)
Xuzhou Medical College (CN), Wenzhou Medical University (CN)
Good health and well-being
Openalex Percentile: Top 76%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.