Research on nighttime IPPG algorithm based on ROI delay expansion and fundamental frequency constrained FastICA

<i>Objective.</i>This study aims to enhance the accuracy and reliability of imaging photoplethysmography (IPPG) for heart rate (HR) measurements during nighttime by introducing an innovative approach that combines fast independent component analysis (FastICA) with a<b>T</b>ime-<b>D</b>elayed<b>M</b>ulti-<b>D</b>imensional<b>E</b>xtended<b>R</b>egions<b>o</b>f<b>I</b>nterest<b>Ex</b>traction (<b>TDMDE-ROI-Ex</b>) technique, specifically tailored to overcome the challenges posed by motion artefacts and the difficulty in identifying regions of interest (ROIs).<i>Approach.</i>This research employs a dual-method strategy for the precise extraction of ROIs and robust processing of HR signals in nighttime IPPG scenarios. Initially, a face detection algorithm is integrated with a grayscale clustering technique to pinpoint optimal ROIs. This is followed by the application of the mutual information delay method to synthesize multi-channel IPPG signals. Concurrently, the<b>HR</b>'s<b>F</b>undamental<b>F</b>requency is leveraged as a prior<b>C</b>onstraint within the iterative process of<b>FastICA</b>(<b>HRFFC-FastICA</b>), mitigating the susceptibility to initial value fluctuations inherent in FastICA. The synergistic application of these methodologies substantially bolsters the stability and robustness of nighttime HR measurements, particularly in conditions characterized by significant motion.<i>Main results.</i>The efficacy of the proposed method, which incorporates HRFFC-FastICA, is initially validated through performance testing using the MR-NIRP dataset. This step serves to assess the practicality of the approach for nighttime IPPG HR measurements. Following this, a series of modular ablation studies and comparative evaluations against current nighttime IPPG algorithms are executed. The statistical outcomes demonstrate that our method achieves a mean absolute error (MAE) of 4.57 beats per minute (bpm) and a root mean squared error (RMSE) of 5.95 bpm. In direct comparison with prominent algorithms such as SparsePPG and PhysNet, the method exhibits a notable enhancement in MAE by up to 8.39 bpm and a significant decrease in RMSE by 17.83 bpm. The 95% confidence interval of the Bland-Altman graph of this method is between 9.5 and -12.8 bpm. Compared to other comparable methods, this interval is significantly narrower, with a width nearly half that of alternative approaches, indicating superior precision and reliability.<i>Significance.</i>The significance of this research is highlighted by the experimental outcomes that demonstrate the considerable advantages of the TDMDE-ROI-Ex method. This technique significantly reduces reliance on facial motion, which is crucial for accurately identifying facial skin colour regions of interest. Moreover, integrating the HRFFC-FastICA method effectively counteracts the effects of motion artefacts and the initial value sensitivity inherent in the FastICA process. The introduction of this methodology into nighttime IPPG monitoring significantly strengthens the system's robustness and stability, thereby extending the range of IPPG technology applications and improving its overall measurement performance.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2025-06-19
DOI
https://doi.org/10.1088/1361-6579/ade653
Primary Topic
Blind Source Separation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on nighttime IPPG algorithm based on ROI delay expansion and fundamental frequency constrained FastICA

Li Peng, Peng Han, Kaiqing Luo, Jian Qiu et al.
Physiological Measurement
Blind Source Separation Techniques
article

Research on nighttime IPPG algorithm based on ROI delay expansion and fundamental frequency constrained FastICA

Li Peng, Peng Han, Kaiqing Luo, Jian Qiu, Dongmei Liu, Miao Chen, Jiang Wu
article en

Abstract

<i>Objective.</i>This study aims to enhance the accuracy and reliability of imaging photoplethysmography (IPPG) for heart rate (HR) measurements during nighttime by introducing an innovative approach that combines fast independent component analysis (FastICA) with a<b>T</b>ime-<b>D</b>elayed<b>M</b>ulti-<b>D</b>imensional<b>E</b>xtended<b>R</b>egions<b>o</b>f<b>I</b>nterest<b>Ex</b>traction (<b>TDMDE-ROI-Ex</b>) technique, specifically tailored to overcome the challenges posed by motion artefacts and the difficulty in identifying regions of interest (ROIs).<i>Approach.</i>This research employs a dual-method strategy for the precise extraction of ROIs and robust processing of HR signals in nighttime IPPG scenarios. Initially, a face detection algorithm is integrated with a grayscale clustering technique to pinpoint optimal ROIs. This is followed by the application of the mutual information delay method to synthesize multi-channel IPPG signals. Concurrently, the<b>HR</b>'s<b>F</b>undamental<b>F</b>requency is leveraged as a prior<b>C</b>onstraint within the iterative process of<b>FastICA</b>(<b>HRFFC-FastICA</b>), mitigating the susceptibility to initial value fluctuations inherent in FastICA. The synergistic application of these methodologies substantially bolsters the stability and robustness of nighttime HR measurements, particularly in conditions characterized by significant motion.<i>Main results.</i>The efficacy of the proposed method, which incorporates HRFFC-FastICA, is initially validated through performance testing using the MR-NIRP dataset. This step serves to assess the practicality of the approach for nighttime IPPG HR measurements. Following this, a series of modular ablation studies and comparative evaluations against current nighttime IPPG algorithms are executed. The statistical outcomes demonstrate that our method achieves a mean absolute error (MAE) of 4.57 beats per minute (bpm) and a root mean squared error (RMSE) of 5.95 bpm. In direct comparison with prominent algorithms such as SparsePPG and PhysNet, the method exhibits a notable enhancement in MAE by up to 8.39 bpm and a significant decrease in RMSE by 17.83 bpm. The 95% confidence interval of the Bland-Altman graph of this method is between 9.5 and -12.8 bpm. Compared to other comparable methods, this interval is significantly narrower, with a width nearly half that of alternative approaches, indicating superior precision and reliability.<i>Significance.</i>The significance of this research is highlighted by the experimental outcomes that demonstrate the considerable advantages of the TDMDE-ROI-Ex method. This technique significantly reduces reliance on facial motion, which is crucial for accurately identifying facial skin colour regions of interest. Moreover, integrating the HRFFC-FastICA method effectively counteracts the effects of motion artefacts and the initial value sensitivity inherent in the FastICA process. The introduction of this methodology into nighttime IPPG monitoring significantly strengthens the system's robustness and stability, thereby extending the range of IPPG technology applications and improving its overall measurement performance.

Physiological MeasurementVol. 46(6)
South China Normal University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Guangzhou Municipal Science and Technology Project, Science and Technology Planning Project of Guangdong Province, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 84%
Blind Source Separation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.