A Challenging Case of Endoscopic Retrograde Cholangiopancreatography Due to an Intradiverticular Papilla

Periampullary diverticulum (PAD) is often encountered and associated with increased technical complexity and risk of procedural failure, particularly when the papilla is located within the diverticular lumen. We report a case of a 52-year-old male patient with biliary leakage secondary to metastatic colorectal carcinoma, in whom standard ERCP attempts failed due to the papilla's position within PAD. Given the challenging anatomy, endoscopic ultrasonography (EUS) was employed to evaluate biliary anatomy and facilitate guided access. Utilizing a cautery-enhanced lumen-apposing metal stent (LAMS), a successful EUS-guided choledochoduodenostomy was performed under fluoroscopic guidance, resulting in adequate biliary drainage without complications. A follow-up at two weeks demonstrated clinical improvement (normalizing bilirubin levels) and resolution of the biliary leakage. This case illustrates the potential utility of EUS-guided lumen-apposing stent placement, specifically the Hot-Axios, as a minimally invasive alternative in difficult biliary interventions involving PAD, with implications for reducing procedural time and improving success rates in anatomically complex scenarios.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-06-19
DOI
https://doi.org/10.7759/cureus.86383
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Challenging Case of Endoscopic Retrograde Cholangiopancreatography Due to an Intradiverticular Papilla

Gürhan Şışman, Mustafa Süveran, Recep Çeçen, Can Boynukara
Cureus
Gallbladder and Bile Duct Disorders
article

A Challenging Case of Endoscopic Retrograde Cholangiopancreatography Due to an Intradiverticular Papilla

Gürhan Şışman, Mustafa Süveran, Recep Çeçen, Can Boynukara
article en

Abstract

Periampullary diverticulum (PAD) is often encountered and associated with increased technical complexity and risk of procedural failure, particularly when the papilla is located within the diverticular lumen. We report a case of a 52-year-old male patient with biliary leakage secondary to metastatic colorectal carcinoma, in whom standard ERCP attempts failed due to the papilla's position within PAD. Given the challenging anatomy, endoscopic ultrasonography (EUS) was employed to evaluate biliary anatomy and facilitate guided access. Utilizing a cautery-enhanced lumen-apposing metal stent (LAMS), a successful EUS-guided choledochoduodenostomy was performed under fluoroscopic guidance, resulting in adequate biliary drainage without complications. A follow-up at two weeks demonstrated clinical improvement (normalizing bilirubin levels) and resolution of the biliary leakage. This case illustrates the potential utility of EUS-guided lumen-apposing stent placement, specifically the Hot-Axios, as a minimally invasive alternative in difficult biliary interventions involving PAD, with implications for reducing procedural time and improving success rates in anatomically complex scenarios.

CureusVol. 17(6)
Acıbadem University (TR), Istanbul University-Cerrahpaşa (TR), Acıbadem Adana Hospital (TR)
Zero hunger
Openalex Percentile: Top 76%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.