Automated office blood pressure measurement: a Hypertension Australia and National Hypertension Taskforce of Australia position statement

Hypertension is the most common problem managed in Australian general practice, yet most adults with hypertension do not have their blood pressure (BP) treated to target. Hypertension diagnosis and management rely upon accurate BP measurements performed using a standardised protocol. However, health system barriers prevent doctors from following measurement protocols, leading to inaccurate BP assessments. A practical BP measurement protocol that can be widely implemented is urgently warranted. Automated office BP (AOBP) is the recommended measurement standard for the diagnosis and management of hypertension. AOBP involves using a validated automated upper-arm cuff BP device programmed to record multiple BP readings at set intervals starting after a rest period. It is done by a trained operator using a standardised protocol in a quiet setting with the correct patient setup, no distractions, and in the absence of a doctor. The device automatically calculates the average of the AOBP recordings and this is comparable to the 24-h ambulatory BP daytime mean. The hypertension threshold based on AOBP is 135/85 mmHg. AOBP can also be applied in other community settings (e.g. pharmacies), provided all the above criteria are met along with communication of results to the person's usual general practitioner. In Australia, nation-wide systematic implementation of evidence based AOBP measurement is strongly recommended. This standardised approach will support healthcare professionals, especially general practitioners, in obtaining high-quality BP values with increasing confidence in clinical decision-making. Policy and practice changes, to address barriers and provide enabling mechanisms for sustained implementation of AOBP, are required.

Authors

Institutions

Publication Details

Journal
Journal of Hypertension
Published
2025-06-18
DOI
https://doi.org/10.1097/hjh.0000000000004079
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated office blood pressure measurement: a Hypertension Australia and National Hypertension Taskforce of Australia position statement

Charlotte Hespe, Anthony Rodgers, Tim Usherwood, Elizabeth Halcomb et al.
Journal of Hypertension
Blood Pressure and Hypertension Studies
article

Automated office blood pressure measurement: a Hypertension Australia and National Hypertension Taskforce of Australia position statement

Charlotte Hespe, Anthony Rodgers, Tim Usherwood, Elizabeth Halcomb, Nigel Stocks, Markus Peter Schlaich, Amanda Samarawickrama, Sharon James, Aletta Elisabeth Schutte, Natalie C. Ward, Garry Jennings, M. Stowasser, James E. Sharman, Mark Nelson
article en

Abstract

Hypertension is the most common problem managed in Australian general practice, yet most adults with hypertension do not have their blood pressure (BP) treated to target. Hypertension diagnosis and management rely upon accurate BP measurements performed using a standardised protocol. However, health system barriers prevent doctors from following measurement protocols, leading to inaccurate BP assessments. A practical BP measurement protocol that can be widely implemented is urgently warranted. Automated office BP (AOBP) is the recommended measurement standard for the diagnosis and management of hypertension. AOBP involves using a validated automated upper-arm cuff BP device programmed to record multiple BP readings at set intervals starting after a rest period. It is done by a trained operator using a standardised protocol in a quiet setting with the correct patient setup, no distractions, and in the absence of a doctor. The device automatically calculates the average of the AOBP recordings and this is comparable to the 24-h ambulatory BP daytime mean. The hypertension threshold based on AOBP is 135/85 mmHg. AOBP can also be applied in other community settings (e.g. pharmacies), provided all the above criteria are met along with communication of results to the person's usual general practitioner. In Australia, nation-wide systematic implementation of evidence based AOBP measurement is strongly recommended. This standardised approach will support healthcare professionals, especially general practitioners, in obtaining high-quality BP values with increasing confidence in clinical decision-making. Policy and practice changes, to address barriers and provide enabling mechanisms for sustained implementation of AOBP, are required.

Journal of HypertensionVol. 43(9)
University of Notre Dame (US), The University of Sydney (AU), University of Tasmania (AU), The University of Queensland (AU), The University of Western Australia (AU), University of Wollongong (AU), Royal Perth Hospital (AU), Hospital Research Foundation (AU), UNSW Sydney (AU), Westmead Institute (AU), George Institute for Global Health (CN), RPH Research Foundation, Monash University (AU), The University of Adelaide (AU)
Peace, Justice and strong institutions
Openalex Percentile: Top 76%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.