A Smartwatch or Just a Watch? A Validation Study of the Smartwatch KC08 for Measuring Blood Pressure

(1) Background: The use of wearable cuffless devices has emerged as an out-of-office blood pressure (BP) monitor device to improve the management of hypertension. We aimed to validate a new, low-cost smartwatch for the measurement of BP and, secondarily, to assess its reliability for the measurement of blood oxygen saturation (SpO<sub>2</sub>) and heart rate. (2) Methods: We compared 1000 pairs of measurements (n = 100) acquired by a smartwatch (KC08) with those measured by a reference device. (3) Results: A total of 100 participants (41 ± 18 years) completed the measurements. The values for the systolic and diastolic BP, heart rate and SpO<sub>2</sub> measured with the Smartwatch KC08 and the reference devices differed significantly (<i>p</i> < 0.05). In addition, the Smartwatch KC08 showed a low variability and poor reliability for all the assessed outcomes except for the heart rate. Moreover, no significant heteroscedasticity was observed for the heart rate measured by the Smartwatch KC08 and the reference sphygmomanometer. (4) Conclusions: The main findings of the present study suggest that the Smartwatch KC08 is not yet suitable for daily clinical practice, although it showed low intra-subject variability and reliability for the resting heart rate.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-18
DOI
https://doi.org/10.3390/s25123793
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Smartwatch or Just a Watch? A Validation Study of the Smartwatch KC08 for Measuring Blood Pressure

Susana López‐Ortiz, José Pinto-Fraga, Saúl Peñín‐Grandes, Celia García‐Chico et al.
Sensors
Blood Pressure and Hypertension Studies
article

A Smartwatch or Just a Watch? A Validation Study of the Smartwatch KC08 for Measuring Blood Pressure

Susana López‐Ortiz, José Pinto-Fraga, Saúl Peñín‐Grandes, Celia García‐Chico, Sergio Maroto‐Izquierdo, Alejandro Santos‐Lozano, Lisa Musso-Daury
article en

Abstract

(1) Background: The use of wearable cuffless devices has emerged as an out-of-office blood pressure (BP) monitor device to improve the management of hypertension. We aimed to validate a new, low-cost smartwatch for the measurement of BP and, secondarily, to assess its reliability for the measurement of blood oxygen saturation (SpO<sub>2</sub>) and heart rate. (2) Methods: We compared 1000 pairs of measurements (n = 100) acquired by a smartwatch (KC08) with those measured by a reference device. (3) Results: A total of 100 participants (41 ± 18 years) completed the measurements. The values for the systolic and diastolic BP, heart rate and SpO<sub>2</sub> measured with the Smartwatch KC08 and the reference devices differed significantly (<i>p</i> < 0.05). In addition, the Smartwatch KC08 showed a low variability and poor reliability for all the assessed outcomes except for the heart rate. Moreover, no significant heteroscedasticity was observed for the heart rate measured by the Smartwatch KC08 and the reference sphygmomanometer. (4) Conclusions: The main findings of the present study suggest that the Smartwatch KC08 is not yet suitable for daily clinical practice, although it showed low intra-subject variability and reliability for the resting heart rate.

SensorsVol. 25(12)
Universidad Europea Miguel de Cervantes (ES), Research Institute Hospital 12 de Octubre (ES)
Openalex Percentile: Top 76%
Blood Pressure and Hypertension Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.