Oxidant Canister Cleaning in Preparation for Sampling and Analyzing Airborne Ethylene Oxide and Other VOCs

Volatile organic compounds (VOCs) such as ethylene oxide (EtO) grow with time in the blank levels of canisters used to sample, store, and analyze said compounds despite cleaning with the current state-of-the-art methods. This problem has existed for the air measurement and monitoring community since the inception of air sampling with canisters in the early 1980s. It has been postulated that this growth is due to the oxidative degradation of canister residues containing higher-molecular-weight compounds and/or particulate matter (PM). The current manuscript describes the use of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) for the effective removal of EtO, other VOCs, and/or their presumed precursors while leaving inert residuals. Results demonstrate that 10 heavily contaminated canisters, subjected to a 7 day zero-air verification, had EtO concentrations averaging 7.50 ppb<sub>v</sub> and 47 ppt<sub>v</sub> for traditional and proposed oxidant cleaning methods, respectively. Results also demonstrate that 19 of 20 lightly contaminated canisters with EtO concentrations above 20 ppt<sub>v</sub>, despite traditional cleaning, had been reduced to nondetectable levels with the recommended oxidant canister cleaning approach. In addition, these 19 canisters passed a 7 day known-standard verification of 150 ppt<sub>v</sub> to confirm that there were no biases associated with the proposed oxidant cleaning method. The heavily and lightly contaminated canisters were evaluated for cleanliness and recoveries using U.S. EPA Method TO-15 and Draft Method 327, respectively. The oxidant cleaning method, results, discussion, and opportunities for future work are addressed in the current manuscript.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-06-18
DOI
https://doi.org/10.1021/acsomega.5c02687
Citations
1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oxidant Canister Cleaning in Preparation for Sampling and Analyzing Airborne Ethylene Oxide and Other VOCs

Brian Jones, Jason S. Herrington, Jason Hoisington
1 citations
ACS Omega
Air Quality Monitoring and Forecasting
0.80
article

Oxidant Canister Cleaning in Preparation for Sampling and Analyzing Airborne Ethylene Oxide and Other VOCs

Brian Jones, Jason S. Herrington, Jason Hoisington
article en
1 citations

Abstract

Volatile organic compounds (VOCs) such as ethylene oxide (EtO) grow with time in the blank levels of canisters used to sample, store, and analyze said compounds despite cleaning with the current state-of-the-art methods. This problem has existed for the air measurement and monitoring community since the inception of air sampling with canisters in the early 1980s. It has been postulated that this growth is due to the oxidative degradation of canister residues containing higher-molecular-weight compounds and/or particulate matter (PM). The current manuscript describes the use of hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>) for the effective removal of EtO, other VOCs, and/or their presumed precursors while leaving inert residuals. Results demonstrate that 10 heavily contaminated canisters, subjected to a 7 day zero-air verification, had EtO concentrations averaging 7.50 ppb<sub>v</sub> and 47 ppt<sub>v</sub> for traditional and proposed oxidant cleaning methods, respectively. Results also demonstrate that 19 of 20 lightly contaminated canisters with EtO concentrations above 20 ppt<sub>v</sub>, despite traditional cleaning, had been reduced to nondetectable levels with the recommended oxidant canister cleaning approach. In addition, these 19 canisters passed a 7 day known-standard verification of 150 ppt<sub>v</sub> to confirm that there were no biases associated with the proposed oxidant cleaning method. The heavily and lightly contaminated canisters were evaluated for cleanliness and recoveries using U.S. EPA Method TO-15 and Draft Method 327, respectively. The oxidant cleaning method, results, discussion, and opportunities for future work are addressed in the current manuscript.

ACS OmegaVol. 10(25)
Restek (United States) (US), MatTek Corporation (United States) (US)
Openalex Percentile: Top 28%
Air Quality Monitoring and Forecasting
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Oxidant Canister Cleaning in Preparation for Sampling and Analyzing Airborne Ethylene Oxide and Other VOCs — Brian Jones, Jason S. Herrington, et al. · ACS Omega (2025) | TGRS Research Map | TGRS