Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor

Early detection and continuous monitoring of diseases are critical to improving patient outcomes, treatment adherence, and diagnostic accuracy. Traditional melanoma diagnosis relies primarily on visual assessment and biopsy, with reported accuracies ranging from 50% to 90% and significant inter-observer variability. Among emerging diagnostic technologies, Raman spectroscopy has demonstrated considerable promise for non-invasive disease detection, particularly in early-stage skin cancer identification. A portable, real-time Raman spectroscopy system could significantly enhance diagnostic precision, reduce biopsy reliance, and expedite diagnosis. However, miniaturization of Raman spectrometers for portable use faces significant challenges, including weak signal intensity, fluorescence interference, and inherent trade-offs between spectral resolution and the signal-to-noise ratio. Recent advances in silicon photonics present promising solutions by facilitating efficient light collection, enhancing optical fields via high-index-contrast waveguides, and allowing compact integration of photonic components. This work introduces a numerical analysis of an integrated digital Fourier transform spectrometer implemented on a silicon-nitride (SiN) platform, specifically designed for Raman spectroscopy. The proposed system employs a switch-based digital Fourier transform spectrometer architecture coupled with a single optical power meter for detection. Utilizing a regularized regression method, we successfully reconstructed Raman spectra in the 800 cm<sup>-1</sup> to 1800 cm<sup>-1</sup> range, covering spectra of both benign and malignant skin lesions. Our results demonstrate the capability of the proposed system to effectively differentiate various skin cancer types, highlighting its feasibility as a non-invasive diagnostic sensor.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-18
DOI
https://doi.org/10.3390/s25123792
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor

Miguel Ángel Nava Blanco, Gerardo Castañón
Sensors
Photonic and Optical Devices
article

Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor

Miguel Ángel Nava Blanco, Gerardo Castañón
article en

Abstract

Early detection and continuous monitoring of diseases are critical to improving patient outcomes, treatment adherence, and diagnostic accuracy. Traditional melanoma diagnosis relies primarily on visual assessment and biopsy, with reported accuracies ranging from 50% to 90% and significant inter-observer variability. Among emerging diagnostic technologies, Raman spectroscopy has demonstrated considerable promise for non-invasive disease detection, particularly in early-stage skin cancer identification. A portable, real-time Raman spectroscopy system could significantly enhance diagnostic precision, reduce biopsy reliance, and expedite diagnosis. However, miniaturization of Raman spectrometers for portable use faces significant challenges, including weak signal intensity, fluorescence interference, and inherent trade-offs between spectral resolution and the signal-to-noise ratio. Recent advances in silicon photonics present promising solutions by facilitating efficient light collection, enhancing optical fields via high-index-contrast waveguides, and allowing compact integration of photonic components. This work introduces a numerical analysis of an integrated digital Fourier transform spectrometer implemented on a silicon-nitride (SiN) platform, specifically designed for Raman spectroscopy. The proposed system employs a switch-based digital Fourier transform spectrometer architecture coupled with a single optical power meter for detection. Utilizing a regularized regression method, we successfully reconstructed Raman spectra in the 800 cm<sup>-1</sup> to 1800 cm<sup>-1</sup> range, covering spectra of both benign and malignant skin lesions. Our results demonstrate the capability of the proposed system to effectively differentiate various skin cancer types, highlighting its feasibility as a non-invasive diagnostic sensor.

SensorsVol. 25(12)
Tecnológico de Monterrey (MX)
Openalex Percentile: Top 88%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor — Miguel Ángel Nava Blanco, Gerardo Castañón · Sensors (2025) | TGRS Research Map | TGRS