First-in-class hydrazone–pyrazoline sensors for selective detection of Zn <sup>2+</sup> , Cd <sup>2+</sup> , and Hg <sup>2+</sup> in aqueous environments

Six first-in-class hydrazone-pyrazoline fluorescent sensors that selectively detect Zn<sup>2+</sup>, Cd<sup>2+</sup>, and Hg<sup>2+</sup> at three distinct wavelengths in aqueous environments are reported. These novel hybrid sensors are synthesized in just two steps from inexpensive, commercially available materials, enabling rapid generation and screening for desirable photophysical properties. Lead sensor P1 was validated for <i>in situ</i> detection of group 12 metals in river and pond water using a portable, low-cost device. Crucially, this system enabled rapid, naked-eye detection of toxic metals directly in the environment without the need for expensive instrumentation or mains electricity. These findings establish a new direction in pyrazoline sensor research and set a high benchmark for future sensor development.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00639b
Citations
4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First-in-class hydrazone–pyrazoline sensors for selective detection of Zn 2+ , Cd 2+ , and Hg 2+ in aqueous environments

Alexander Ciupa
4 citations
Analytical Methods
Analytical Chemistry and Sensors
2.95
article

First-in-class hydrazone–pyrazoline sensors for selective detection of Zn 2+ , Cd 2+ , and Hg 2+ in aqueous environments

Alexander Ciupa
article en
4 citations

Abstract

Six first-in-class hydrazone-pyrazoline fluorescent sensors that selectively detect Zn<sup>2+</sup>, Cd<sup>2+</sup>, and Hg<sup>2+</sup> at three distinct wavelengths in aqueous environments are reported. These novel hybrid sensors are synthesized in just two steps from inexpensive, commercially available materials, enabling rapid generation and screening for desirable photophysical properties. Lead sensor P1 was validated for <i>in situ</i> detection of group 12 metals in river and pond water using a portable, low-cost device. Crucially, this system enabled rapid, naked-eye detection of toxic metals directly in the environment without the need for expensive instrumentation or mains electricity. These findings establish a new direction in pyrazoline sensor research and set a high benchmark for future sensor development.

Analytical MethodsVol. 17(27)
University of Liverpool (GB)
Research England
Clean water and sanitation
Openalex Percentile: Top 8%
Analytical Chemistry and Sensors
2.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.